RFmx LTE DotNET

Table of Contents

RFmxLteMXModAccResults.FetchSpectralFlatness Method

  • Updated2024-07-17
  • 2 minute(s) read
RFmxLteMXModAccResults.FetchSpectralFlatness Method

RFmxLteMXModAccResultsFetchSpectralFlatness Method

Returns the spectral flatness measurements of the component carrier.
Use "carrier(k)" or "subblock(n)/carrier(k)" as the selector string to read results from this method.

Namespace:  NationalInstruments.RFmx.LteMX
Assembly:  NationalInstruments.RFmx.LteMX.Fx40 (in NationalInstruments.RFmx.LteMX.Fx40.dll) Version: 24.5.0.49283 (24.5.0.49283)

Syntax

public int FetchSpectralFlatness(
	string selectorString,
	double timeout,
	out double range1MaximumToRange1Minimum,
	out double range2MaximumToRange2Minimum,
	out double range1MaximumToRange2Minimum,
	out double range2MaximumToRange1Minimum
)
Public Function FetchSpectralFlatness ( 
	selectorString As String,
	timeout As Double,
	<OutAttribute> ByRef range1MaximumToRange1Minimum As Double,
	<OutAttribute> ByRef range2MaximumToRange2Minimum As Double,
	<OutAttribute> ByRef range1MaximumToRange2Minimum As Double,
	<OutAttribute> ByRef range2MaximumToRange1Minimum As Double
) As Integer

Parameters

selectorString
Type: SystemString
Specifies a selector string comprising of the result name, subblock number, and carrier number. If you do not specify the result name, the default result instance is used. Example:
"subblock0/carrier0"
"result::r1/subblock0/carrier0"
You can use the BuildCarrierString(String, Int32) method to build the selector string.
timeout
Type: SystemDouble
Specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the method waits until the measurement is complete.
range1MaximumToRange1Minimum
Type: SystemDouble
Upon return, contains the peak-to-peak ripple of the EVM equalizer coefficients within the frequency Range1. The frequency Range1 is as defined in section 6.5.2.4.5 of the 3GPP TS 36.521 specification.
range2MaximumToRange2Minimum
Type: SystemDouble
Upon return, contains the peak-to-peak ripple of the EVM equalizer coefficients within the frequency Range2. The frequency Range2 is defined in section 6.5.2.4.5 of the 3GPP TS 36.521 specification.
range1MaximumToRange2Minimum
Type: SystemDouble
Upon return, contains the peak-to-peak ripple of the EVM equalizer coefficients from the frequency Range1 to the frequency Range2. The frequency Range1 and 2 are defined in the section 6.5.2.4.5 of the 3GPP TS 36.521 specification.
range2MaximumToRange1Minimum
Type: SystemDouble
Upon return, contains the peak-to-peak ripple of the EVM equalizer coefficients from frequency Range2 to frequency Range1. The frequency Range1 and 2 are defined in section 6.5.2.4.5 of the 3GPP TS 36.521 specification.

Return Value

Type: Int32
Returns the status code of this method. The status code either indicates success or describes a warning condition.