RFmxLteMXSemConfiguration.SetOffsetAbsoluteLimitStart Method

RFmxLteMXSemConfigurationSetOffsetAbsoluteLimitStart Method

Sets the absolute power limit corresponding to the beginning of an offset segment. This value is expressed in dBm.

Namespace:  NationalInstruments.RFmx.LteMX
Assembly:  NationalInstruments.RFmx.LteMX.Fx40 (in NationalInstruments.RFmx.LteMX.Fx40.dll) Version: 24.5.0.49283 (24.5.0.49283)

Syntax

public int SetOffsetAbsoluteLimitStart(
	string selectorString,
	double value
)
Public Function SetOffsetAbsoluteLimitStart ( 
	selectorString As String,
	value As Double
) As Integer

Parameters

selectorString
Type: SystemString
Specifies the offset number and subblock number.
Example:
"subblock0" or
"subblock0/offset0".
You can use the BuildOffsetString(String, Int32) method to build the selector string.
value
Type: SystemDouble
Specifies the absolute power limit corresponding to the beginning of an offset segment. This value is expressed in dBm.

Return Value

Type: Int32
Returns the status code of this method. The status code either indicates success or describes a warning condition.

Remarks

This method sets the value of SemOffsetAbsoluteLimitStart attribute. The default value is -16.5.