RFmxLteMXComponentCarrier.GetDownlinkAutoCellIDDetectionEnabled Method
- Updated2024-07-17
- 1 minute(s) read
RFmxLteMXComponentCarrierGetDownlinkAutoCellIDDetectionEnabled Method
Gets whether to enable autodetection of the cell ID. If the signal being measured does not contain primary and secondary sync signal (PSS/SSS), autodetection of cell ID is not possible. Detected cell ID can be fetched using GetDownlinkDetectedCellID(String, Int32) method.
Namespace: NationalInstruments.RFmx.LteMX
Assembly: NationalInstruments.RFmx.LteMX.Fx40 (in NationalInstruments.RFmx.LteMX.Fx40.dll) Version: 24.5.0.49283 (24.5.0.49283)
Syntax
public int GetDownlinkAutoCellIDDetectionEnabled( string selectorString, out RFmxLteMXDownlinkAutoCellIDDetectionEnabled value )
Public Function GetDownlinkAutoCellIDDetectionEnabled ( selectorString As String, <OutAttribute> ByRef value As RFmxLteMXDownlinkAutoCellIDDetectionEnabled ) As Integer
Parameters
- selectorString
- Type: SystemString
Pass an empty string. The signal name that is passed when creating the signal configuration is used. - value
- Type: NationalInstruments.RFmx.LteMXRFmxLteMXDownlinkAutoCellIDDetectionEnabled
Upon return, contains whether to enable autodetection of the cell ID. If the signal being measured does not contain primary and secondary sync signal (PSS/SSS), autodetection of cell ID is not possible. Detected cell ID can be fetched using GetDownlinkDetectedCellID(String, Int32) method.
Return Value
Type: Int32Returns the status code of this method. The status code either indicates success or describes a warning condition.
Remarks
This method gets the value of DownlinkAutoCellIDDetectionEnabled attribute. The default value is True.