RFmxLteMXAcpConfiguration.SetIFOutputPowerOffsetAuto Method
- Updated2024-07-17
- 1 minute(s) read
RFmxLteMXAcpConfigurationSetIFOutputPowerOffsetAuto Method
Sets whether the measurement computes an appropriate IF output power level offset for the offset channels to improve the dynamic range of the ACP measurement. This method is applicable only when you set the SetMeasurementMethod(String, RFmxLteMXAcpMeasurementMethod) method to DynamicRange.
Namespace: NationalInstruments.RFmx.LteMX
Assembly: NationalInstruments.RFmx.LteMX.Fx40 (in NationalInstruments.RFmx.LteMX.Fx40.dll) Version: 24.5.0.49283 (24.5.0.49283)
Syntax
public int SetIFOutputPowerOffsetAuto( string selectorString, RFmxLteMXAcpIFOutputPowerOffsetAuto value )
Public Function SetIFOutputPowerOffsetAuto ( selectorString As String, value As RFmxLteMXAcpIFOutputPowerOffsetAuto ) As Integer
Parameters
- selectorString
- Type: SystemString
Pass an empty string. The signal name that is passed when creating the signal configuration is used. - value
- Type: NationalInstruments.RFmx.LteMXRFmxLteMXAcpIFOutputPowerOffsetAuto
Specifies whether the measurement computes an appropriate IF output power level offset for the offset channels to improve the dynamic range of the ACP measurement. This method is applicable only when you set the SetMeasurementMethod(String, RFmxLteMXAcpMeasurementMethod) method to DynamicRange.
Return Value
Type: Int32Returns the status code of this method. The status code either indicates success or describes a warning condition.
Remarks
This method sets the value of AcpIFOutputPowerOffsetAuto attribute. The default value is True.