RFmxLteMXAcpConfiguration.SetRbwFilterAutoBandwidth Method
- Updated2024-07-17
- 1 minute(s) read
RFmxLteMXAcpConfigurationSetRbwFilterAutoBandwidth Method
Sets whether the measurement computes the RBW.
Namespace: NationalInstruments.RFmx.LteMX
Assembly: NationalInstruments.RFmx.LteMX.Fx40 (in NationalInstruments.RFmx.LteMX.Fx40.dll) Version: 24.5.0.49283 (24.5.0.49283)
Syntax
public int SetRbwFilterAutoBandwidth( string selectorString, RFmxLteMXAcpRbwAutoBandwidth value )
Public Function SetRbwFilterAutoBandwidth ( selectorString As String, value As RFmxLteMXAcpRbwAutoBandwidth ) As Integer
Parameters
- selectorString
- Type: SystemString
Pass an empty string. The signal name that is passed when creating the signal configuration is used. - value
- Type: NationalInstruments.RFmx.LteMXRFmxLteMXAcpRbwAutoBandwidth
Specifies whether the measurement computes the RBW.
Return Value
Type: Int32Returns the status code of this method. The status code either indicates success or describes a warning condition.
Remarks
This method sets the value of AcpRbwFilterAutoBandwidth attribute. The default value is True.