NI-DCPower .NET fx45 API Reference

Table of Contents

DCPowerOutputSourceOutputCutoff.CurrentMeasureLimitLow Property

  • Updated2024-01-04
  • 2 minute(s) read
DCPowerOutputSourceOutputCutoff.CurrentMeasureLimitLow Property

DCPowerOutputSourceOutputCutoffCurrentMeasureLimitLow Property

Specifies a low limit current value, in amps, for output cutoff. If the measured current falls below this limit, the output is disconnected.

Namespace:  NationalInstruments.ModularInstruments.NIDCPower
Assembly:  NationalInstruments.ModularInstruments.NIDCPower.Fx45 (in NationalInstruments.ModularInstruments.NIDCPower.Fx45.dll) Version: 2023

Syntax

public double CurrentMeasureLimitLow { get; set; }
Public Property CurrentMeasureLimitLow As Double
	Get
	Set

Property Value

Type: Double
Represents a low current threshold for output cutoff.

Remarks

To find out whether an output has fallen below this limit, call the QueryLatchedOutputCutoffState(String, DCPowerOutputCutoffReason) method with OutputCutoffReasonCurrentMeasureLow as the outputCutoffReason.

Note Note
NI-DCPower uses the terms "source" and "output". However, while sinking with electronic loads and SMUs these correspond to "sinking" and "input", respectively.
Note Note
This property is not supported by all instruments. Refer to the Supported Properties by Device topic in the NI DC Power Supplies and SMUs Help for information about supported instruments.