RFmxInstrMX.GetStartTriggerDigitalEdge Method
- Updated2024-07-17
- 1 minute(s) read
RFmx
Gets the active edge for the start trigger. This method is used only when you set the SetStartTriggerType(String, RFmxInstrMXStartTriggerType) method to DigitalEdge.
Namespace: NationalInstruments.RFmx.InstrMX
Assembly: NationalInstruments.RFmx.InstrMX.Fx40 (in NationalInstruments.RFmx.InstrMX.Fx40.dll) Version: 24.5.0.49285 (24.5.0.49285)
Syntax
public int GetStartTriggerDigitalEdge( string selectorString, out RFmxInstrMXStartTriggerDigitalEdge value )
Public Function GetStartTriggerDigitalEdge ( selectorString As String, <OutAttribute> ByRef value As RFmxInstrMXStartTriggerDigitalEdge ) As Integer
Parameters
- selectorString String
- Pass an empty string.
- value RFmxInstrMXStartTriggerDigitalEdge
- Upon return, contains the active edge for the start trigger. This method is used only when you set the SetStartTriggerType(String, RFmxInstrMXStartTriggerType) method to DigitalEdge.
Return Value
Int32Returns the status code of this method. The status code either indicates success or describes a warning condition.
Remarks
This method gets the value of StartTriggerDigitalEdge attribute.The default value is Rising. Supported devices: PXIe-5644/5645/5646, PXIe-5663/5663E/5665/5668, PXIe-5820/5830/5831/5832/5840/5841/5842/5860