RFmxInstrMX.GetLOVcoFrequencyStepSize Method
- Updated2024-07-17
- 1 minute(s) read
RFmx
Gets the step size for tuning the internal voltage-controlled oscillator (VCO) used to generate the LO signal. The valid values for LO1 include 1 Hz to 50 MHz and for LO2 include 1 Hz to 100 MHz.
Namespace: NationalInstruments.RFmx.InstrMX
Assembly: NationalInstruments.RFmx.InstrMX.Fx40 (in NationalInstruments.RFmx.InstrMX.Fx40.dll) Version: 24.5.0.49285 (24.5.0.49285)
Syntax
public int GetLOVcoFrequencyStepSize( string selectorString, out double value )
Public Function GetLOVcoFrequencyStepSize ( selectorString As String, <OutAttribute> ByRef value As Double ) As Integer
Parameters
- selectorString String
- Pass an empty string.
- value Double
- Upon return, contains the step size for tuning the internal voltage-controlled oscillator (VCO) used to generate the LO signal. The valid values for LO1 include 1 Hz to 50 MHz and for LO2 include 1 Hz to 100 MHz.
Return Value
Int32Returns the status code of this method. The status code either indicates success or describes a warning condition.
Remarks
This method gets the value of LOVcoFrequencyStepSize attribute.The default value is 1 MHz. Supported devices: PXIe-5830/5831/5832