NI-9147 Specifications
- Updated2024-01-12
- 5 minute(s) read
NI-9147 Specifications
Definitions
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
- Typical specifications describe the performance met by a majority of models.
- Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
Specifications are Typical unless otherwise noted.
Conditions
Specifications are valid for the range -40 °C to 70 °C unless otherwise noted.
Operating System
Supported operating system | NI Linux Real-Time (32-bit) | ||||||
| |||||||
Memory
Network
Network interface | 10Base-T, 100Base-T, 1000Base-T Ethernet |
Compatibility | IEEE 802.3 |
Communication rates | 10 Mb/s, 100 Mb/s, 1,000 Mb/s auto-negotiated, half/full-duplex |
Maximum cabling distance | 100 m/segment |
Internal Real-Time Clock
Accuracy | 5 ppm |
USB Port
| |||||||
Reconfigurable FPGA
Type | Xilinx Zynq-7000, XC7Z020 All Programmable SoC |
Number of logic cells | 85,000 |
Number of flip-flops | 106,400 |
Number of 6-input LUTs | 53,200 |
Number of DSP slices (18 × 25 multipliers) | 220 |
Available block RAM | 4480 kbits |
Number of DMA channels | 16 |
Number of logical interrupts | 32 |
Battery Life
Typical battery life with power applied to power connector | 10 years |
Typical battery life in storage at 55 °C | 5.7 years |
Minimum battery life in storage at 85 °C | 5.3 years |
Safety Voltages
V terminal to C terminal | 30 V maximum, Measurement Category I |
Measurement Category
Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Environmental Characteristics
| |||||||||||||
| |||||||||||||
Ingress protection | IP40 | ||||||||||||
Pollution Degree | 2 | ||||||||||||
Maximum altitude | 5,000 m | ||||||||||||
| |||||||||||||
Indoor use only.[3]3 Use NI-9917 and NI-9918 industrial enclosures to protect the device in harsh, dirty, or wet environments.
Power Requirements
Voltage input range | 9 V DC to 30 V DC |
Reverse-voltage protection | 30 V DC maximum |
Maximum power input, with four C Series modules | 11 W |
Maximum power input, without C Series modules | 7 W |
Physical Characteristics
Weight (unloaded) | 680 g (23.98 oz) | ||||||||||||
Dimensions (unloaded) | 178.2 mm × 87.3 mm × 64.3 mm (7.01 in. × 3.44 in. × 2.50 in.) | ||||||||||||
| |||||||||||||
| |||||||||||||
1 LabVIEW FPGA Module is not required when using Scan Interface mode. To program the user-accessible FPGA on the NI-9147, LabVIEW FPGA Module is required.
2 Formatted capacity of nonvolatile memory may be slightly less than this value.
3 Use NI-9917 and NI-9918 industrial enclosures to protect the device in harsh, dirty, or wet environments.