You can change the Maximum number of points as required.

To change the analysis title from its default, enter text in the Title for analysis field.

Digitization of Analog Signals

You can digitize analog signals for the following analyses:

  • Transient Analysis
  • DC Sweep Analysis
  • Parameter Sweep
  • Temperature Sweep Analysis
  • User-Defined Analysis.

To change the digitization thresholds, edit the following as desired:

  • Digital high threshold—If an analog signal is above this value, it is digitized as High.
  • Digital low threshold—If an analog signal is below this value, it is digitized as Low.

If an analog signal's value is between the Digitization high threshold and the Digitization low threshold, it will be digitized as Unknown.

Custom Analysis Options

If an analysis does not perform as expected, or encounters simulation problems, you may need to set custom analysis options.

Complete the following steps to set custom analysis options:

  1. Enable Use custom settings and click Customize.

    The Custom Analysis Options dialog box appears.

      You should have a general knowledge of the SPICE simulation engine before altering the default settings under this option.

  2. Change the desired settings in the Custom Analysis Options dialog box.
  3. Click OK to return to the Analysis options tab.

Refer to the Custom Analysis Options section for a complete list of the available analysis options.