DA200025X Specifications
- Updated2026-03-09
- 4 minute(s) read
DA200025X Specifications
DA200025X Specifications
The DA200025X is an active differential probe with 2 GHz input bandwidth and a 25:1 attenuation ratio, allowing it to be used with NI high-speed digitizers and oscilloscopes. This document contains the detailed product specifications.
Typical values listed in this document are representative of an average unit operating at room temperature. The probe and connected measurement instrument should be warmed up for at least 20 minutes prior to use. Check the module-specific documentation for the oscilloscope warm-up time. Specifications are subject to change without notice.
Typical specifications are unwarranted values that are representative of a majority (90%) of units within certain operating conditions and include the effects of temperature and uncertainty unless otherwise noted.
Electrical Specifications
All specifications are typical.
| Specification | Value | Comment |
|---|---|---|
| Physical connector | BNC | BNC connection to the scope |
| Bandwidth (–3 dB) | 2 GHz | Dual-signal pin configuration |
| Attenuation ratio | 25:1 | — |
| Input impedance | 500 kΩ || 1.2 pF | Either input to ground |
| Gain accuracy | ±2% | — |
| Differential input voltage | ±20 V | DC + peak AC |
| Common-mode input voltage | ±60 V | DC + peak AC |
| Absolute maximum rated input voltage | ±60 V | DC + peak AC Either input to ground |
| Single-ended output voltage | ±1.5 V | Into 50 Ω load |
| Output impedance | 50 Ω | — |
| Offset | ±5 mV | — |
| Common-mode rejection ratio (CMRR) | DC: > 70 dB 1 MHz: > 50 dB 10 MHz: > 45 dB 100 MHz: > 35 dB 500 MHz: > 25 dB 1 GHz: > 25 dB |
— |
Derating Curve
Figure 1 shows a DA200025X typical derating curve of absolute maximum input voltage (either input to ground).
Power Requirements
| Specification | Value |
|---|---|
| Power supply input range | 5 V (500 mA) to 9 V (300 mA) |
| Required power source | Supplied USB power cable |
Physical Specifications
| Specification | Value | Comment |
|---|---|---|
| Approximate weight | 103 g (3.6 oz) | Not including power supply unit or attached accessories |
| Output BNC cable length | 1.3 m (51.2 in.) | — |
| Probe main body dimensions | 78.62 mm × 18.5 mm × 10.86 mm (3.1 in. × 0.7 in. × 0.4 in.) | — |
| Included power supply cable length | 2 m (78.7 in.) | — |
Environmental
| Specification | Value |
|---|---|
| Operating temperature | 0 °C to +50 °C |
| Storage temperature | –40 °C to +71 °C |
| Operating relative humidity | 80% relative humidity for temperatures up to +31 °C, decreasing linearly to 40% at +50 °C |
| Storage relative humidity | 95 % relative humidity for temperatures up to +40 °C |
Compliance and Certifications
Safety
- IEC 61010-031
- EN 61010-031
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
- EN 61326-1 (IEC 61326-1): Class B emissions; Basic immunity
- EN 55011 (CISPR 11): Group 1, Class B emissions
- AS/NZS CISPR 11: Group 1, Class B emissions
- FCC 47 CFR Part 15B: Class B emissions
- ICES-001: Class B emissions
Online Product Certification
To obtain product certifications and the Declaration of Conformity (DoC) for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.
EU and UK Customers
电子信息产品污染控制管理办法(中国RoHS)
NI Services
Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples.
Visit ni.com/services to learn about NI service offerings such as calibration options, repair, and replacement.
Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI.
NI corporate headquarters is located at 11500 N Mopac Expwy, Austin, TX, 78759-3504, USA.