ATE Core Configurations Generation 2 System Physical Characteristics
- Updated2025-07-11
- 5 minute(s) read
ATE Core Configurations Generation 2 System Physical Characteristics
The listed ATE Core Configurations Generation 2 system dimensions include the rack, power entry panel, and power distribution unit.
Note For systems that include
integrated equipment, the weight added by that equipment must be considered for the
maximum weight. Weights for integrated equipment can be found in the equipment user
manual.
ATE-15U Dimensions and Weight
Note ATE-15U weight includes frame, rack control unit (RCU), RCU
AC/DC 120 W PS, fan panel, RMX-10151 single-phase power distribution unit (PDU), RMX-10140-24S2 single-phase power entry panel (PEP),
front and rear door, and fan AC/DC 240 W PS. Weight
does not include any ballast weights.
Note ATE-15U maximum weight includes base configuration and all
equipment installed, stored, or attached to rack. ATE-15U rack casters and frame can withstand a maximum weight of
272 kg (600
lb)
| Specification | Value |
|---|---|
| Dimension of configured core | (888 mm + DIM A) × 679 mm × 898 mm ((35.0 in. + DIM A) × 26.7 in. × 35.3 in.) |
| Typical configuration weight | 94 ± 0.5 kg (207.2 ± 1.1 lb) |
| Maximum weight | 272 kg (600 lb) |
| PEP Model | DIM A Value |
|---|---|
| RMX-10140-16S2 | 52 mm (2.0 in.) |
| RMX-10140-24S2 | 47 mm (1.8 in.) |
ATE-38U/44U Dimensions and Weight
Note ATE-38U/44U weight includes frame, rack
control unit (RCU), RCU AC/DC 120 W PS, RMX-10153-D2V 3-phase power distribution unit (PDU),
AUX DC 600 PDU, AUX DC 1200 PDU, RMX-10140-50D2P power entry panel (PEP), three RMX-10151 single-phase PDUs, two fan panels, one fan
AC/DC 480 W PS, rear door, and I/O panel upgrade.
Weight does not include any ballast weights.
Note ATE-38U/44U maximum weight includes base configuration and all
equipment installed, stored, or attached to rack. ATE-38U/44U rack casters and frame can withstand a maximum weight
between 454 kg (1000
lb) and 544 kg (1200 lb) determined by the selected rack casters, evenly distributed among
each caster.
| Specification | Value | |
|---|---|---|
| Dimension of configured core | (888 mm + DIM A) × 679 mm × 1972 mm ((35.0 in. + DIM A) × 26.7 in. × 77.6 in.) | |
| Typical configuration weight | 151 ± 0.5 kg (332.9 ± 1.1 lb) | |
| Maximum weight | Normal rack casters | 454 kg (1000 lb) |
| ESD rack casters | 544 kg( 1200 lb) | |
| Maximum main rack space mounting weight | Normal rack casters | 310 kg (683 lb) |
| ESD rack casters | 380 kg (838 lb) | |
| Specification | Value | |
|---|---|---|
| Dimension of configured core | (888 mm + DIM A) × 679 mm × 2182 mm ((35.0 in. + DIM A) × 26.7 in. × 85.9 in.) | |
| Typical configuration weight | 160 ± 0.5 kg (352.7 ± 1.1 lb) | |
| Maximum weight | Normal rack casters | 454 kg (1000 lb) |
| ESD rack casters | 544 kg( 1200 lb) | |
| Maximum main rack space mounting weight | Normal rack casters | 310 kg (683 lb) |
| ESD rack casters | 380 kg (838 lb) | |
| PEP Model | DIM A Value |
|---|---|
| RMX-10140-16S2 | 52 mm (2.0 in.) |
| RMX-10140-24S2 | 47 mm (1.8 in.) |
| RMX-10140-16D2 | 69 mm (2.7 in.) |
| RMX-10140-32D2 | 140 mm (5.5 in.) |
| RMX-10140-16Y2 | 69 mm (2.7 in.) |
| RMX-10140-50D2P, RMX-10140-50Y2P | 166 mm (6.5 in.) |
ATE-38E Primary Rack Dimensions and Weight
Note Weight includes frame, rack control unit
(RCU), RCU AC/DC 120 W PS, RMX-10153-D2V 3-Phase power distribution unit (PDU), AUX DC 600 PDU, AUX
DC 1200 PDU, RMX-10140-50D2P power entry panel (PEP), one RMX-10151 Single-Phase PDU, MRD board, two fan panels, one fan AC/DC 480 W PS, rear door, and basic I/O panel. Weight does
not include any ballast weights.
Note Maximum weight
includes base configuration and all equipment installed, stored, or attached to
rack. Rack casters and frame can withstand a maximum weight of 544 kg (1200 lb),
evenly distributed among each caster.
| Specification | Value |
|---|---|
| Dimension of configured core | (1138 mm + DIM A) × 679 mm × 1972 mm ((44.8 in. + DIM A) × 26.7 in. × 77.6 in.) |
| Typical configuration weight | 157 ± 0.5 kg (346.1 ± 1.1 lb) |
| Maximum weight | 544 kg( 1200 lb) |
| Maximum main rack space mounting weight | 360 kg (794 lb) |
| PEP Model | DIM A Value |
|---|---|
| RMX-10140-16S2 | 52 mm (2.0 in.) |
| RMX-10140-24S2 | 47 mm (1.8 in.) |
| RMX-10140-16D2 | 69 mm (2.7 in.) |
| RMX-10140-32D2 | 140 mm (5.5 in.) |
| RMX-10140-16Y2 | 69 mm (2.7 in.) |
| RMX-10140-50D2P, RMX-10140-50Y2P | 166 mm (6.5 in.) |
ATE-38E Extension Rack Dimensions and Weight
Note Weight includes
frame, AUX DC 1200 PDU, one RMX-10151 Single-Phase
PDU, MRD board, two fan panels, one fan AC/DC 480 W
PS, and rear door. Weight does not include any ballast weights.
Note Maximum weight includes base
configuration and all equipment installed, stored, or attached to rack. Rack casters
and frame can withstand a maximum weight of 544 kg
(1200 lb), evenly distributed among each
caster.
| Specification | Value |
|---|---|
| Dimension of configured core | 1102 mm × 679 mm × 1972 mm (43.4 in. × 26.7 in. × 77.6 in.) |
| Typical configuration weight | 136 ± 0.5 kg (299.8 ± 1.1 lb) |
| Maximum weight | 544 kg (1200 lb) |
| Maximum main rack space mounting weight | 360 kg (794 lb) |
Related Information
- Ventilation Clearances
Clearances are required around an ATE Core Configurations Generation 2 system to ensure proper airflow.