ATE Core Configurations Generation 2 System Physical Characteristics

The listed ATE Core Configurations Generation 2 system dimensions include the rack, power entry panel, and power distribution unit.

Note For systems that include integrated equipment, the weight added by that equipment must be considered for the maximum weight. Weights for integrated equipment can be found in the equipment user manual.

ATE-15U Dimensions and Weight

Note ATE-15U weight includes frame, rack control unit (RCU), RCU AC/DC 120 W PS, fan panel, RMX-10151 single-phase power distribution unit (PDU), RMX-10140-24S2 single-phase power entry panel (PEP), front and rear door, and fan AC/DC 240 W PS. Weight does not include any ballast weights.
Note ATE-15U maximum weight includes base configuration and all equipment installed, stored, or attached to rack. ATE-15U rack casters and frame can withstand a maximum weight of 272 kg (600 lb)
Figure 77. ATE-15U Dimensions


Table 68. ATE-15U Physical Characteristics
Specification Value
Dimension of configured core (888 mm + DIM A) × 679 mm × 898 mm ((35.0 in. + DIM A) × 26.7 in. × 35.3 in.)
Typical configuration weight 94 ± 0.5 kg (207.2 ± 1.1 lb)
Maximum weight 272 kg (600 lb)
Table 69. ATE-15U PEP Dimensional Addition
PEP Model DIM A Value
RMX-10140-16S2 52 mm (2.0 in.)
RMX-10140-24S2 47 mm (1.8 in.)

ATE-38U/44U Dimensions and Weight

Note ATE-38U/44U weight includes frame, rack control unit (RCU), RCU AC/DC 120 W PS, RMX-10153-D2V 3-phase power distribution unit (PDU), AUX DC 600 PDU, AUX DC 1200 PDU, RMX-10140-50D2P power entry panel (PEP), three RMX-10151 single-phase PDUs, two fan panels, one fan AC/DC 480 W PS, rear door, and I/O panel upgrade. Weight does not include any ballast weights.
Note ATE-38U/44U maximum weight includes base configuration and all equipment installed, stored, or attached to rack. ATE-38U/44U rack casters and frame can withstand a maximum weight between 454 kg (1000 lb) and 544 kg (1200 lb) determined by the selected rack casters, evenly distributed among each caster.
Figure 78. ATE-38U Dimensions


Table 70. ATE-38U Physical Characteristics
Specification Value
Dimension of configured core (888 mm + DIM A) × 679 mm × 1972 mm ((35.0 in. + DIM A) × 26.7 in. × 77.6 in.)
Typical configuration weight 151 ± 0.5 kg (332.9 ± 1.1 lb)
Maximum weight Normal rack casters 454 kg (1000 lb)
ESD rack casters 544 kg( 1200 lb)
Maximum main rack space mounting weight Normal rack casters 310 kg (683 lb)
ESD rack casters 380 kg (838 lb)
Figure 79. ATE-44U Dimensions


Table 71. ATE-44U Physical Characteristics
Specification Value
Dimension of configured core (888 mm + DIM A) × 679 mm × 2182 mm ((35.0 in. + DIM A) × 26.7 in. × 85.9 in.)
Typical configuration weight 160 ± 0.5 kg (352.7 ± 1.1 lb)
Maximum weight Normal rack casters 454 kg (1000 lb)
ESD rack casters 544 kg( 1200 lb)
Maximum main rack space mounting weight Normal rack casters 310 kg (683 lb)
ESD rack casters 380 kg (838 lb)
Table 72. ATE-38U/44U PEP Dimensional Addition
PEP Model DIM A Value
RMX-10140-16S2 52 mm (2.0 in.)
RMX-10140-24S2 47 mm (1.8 in.)
RMX-10140-16D2 69 mm (2.7 in.)
RMX-10140-32D2 140 mm (5.5 in.)
RMX-10140-16Y2 69 mm (2.7 in.)
RMX-10140-50D2P, RMX-10140-50Y2P 166 mm (6.5 in.)

ATE-38E Primary Rack Dimensions and Weight

Note Weight includes frame, rack control unit (RCU), RCU AC/DC 120 W PS, RMX-10153-D2V 3-Phase power distribution unit (PDU), AUX DC 600 PDU, AUX DC 1200 PDU, RMX-10140-50D2P power entry panel (PEP), one RMX-10151 Single-Phase PDU, MRD board, two fan panels, one fan AC/DC 480 W PS, rear door, and basic I/O panel. Weight does not include any ballast weights.
Note Maximum weight includes base configuration and all equipment installed, stored, or attached to rack. Rack casters and frame can withstand a maximum weight of 544 kg (1200 lb), evenly distributed among each caster.
Figure 80. ATE-38E Primary Rack Dimensions

Table 73. ATE-38E Primary Rack Physical Characteristics
Specification Value
Dimension of configured core (1138 mm + DIM A) × 679 mm × 1972 mm ((44.8 in. + DIM A) × 26.7 in. × 77.6 in.)
Typical configuration weight 157 ± 0.5 kg (346.1 ± 1.1 lb)
Maximum weight 544 kg( 1200 lb)
Maximum main rack space mounting weight 360 kg (794 lb)
Table 74. ATE-38E PEP Dimensional Addition
PEP Model DIM A Value
RMX-10140-16S2 52 mm (2.0 in.)
RMX-10140-24S2 47 mm (1.8 in.)
RMX-10140-16D2 69 mm (2.7 in.)
RMX-10140-32D2 140 mm (5.5 in.)
RMX-10140-16Y2 69 mm (2.7 in.)
RMX-10140-50D2P, RMX-10140-50Y2P 166 mm (6.5 in.)

ATE-38E Extension Rack Dimensions and Weight

Note Weight includes frame, AUX DC 1200 PDU, one RMX-10151 Single-Phase PDU, MRD board, two fan panels, one fan AC/DC 480 W PS, and rear door. Weight does not include any ballast weights.
Note Maximum weight includes base configuration and all equipment installed, stored, or attached to rack. Rack casters and frame can withstand a maximum weight of 544 kg (1200 lb), evenly distributed among each caster.
Figure 81. ATE-38E Extension Rack Dimensions

Table 75. ATE-38E Extension Rack Physical Characteristics
Specification Value
Dimension of configured core 1102 mm × 679 mm × 1972 mm (43.4 in. × 26.7 in. × 77.6 in.)
Typical configuration weight 136 ± 0.5 kg (299.8 ± 1.1 lb)
Maximum weight 544 kg (1200 lb)
Maximum main rack space mounting weight 360 kg (794 lb)