SystemLink Introduction

SystemLink helps manage and optimize test systems within a lab or organization.

SystemLink Key Features

SystemLink has common aspects across Base, Full, Professional, and Enterprise.

Note For more information on the differences between the editions of SystemLink, refer to Select Your NI SystemLink Edition.
Table 1. Common Aspects of SystemLink
Common Aspect Description
Core Experience
SystemLink provides the following shared foundation across all editions:
  • Built-in and custom dashboards
  • Jupyter notebook authoring
  • Alarms
  • Collaborative comments
  • Custom web app hosting
Systems Management
SystemLink manages systems in the following ways:
  • Remote, at scale, deployment of software to connected test stations
  • Maintains a centralized package repository
  • Tracks system health and calibration status
  • Manages physical asset locations through QR codes
Operations

SystemLink organizes lab work through DUT tracking, test plans, reservations, and work items. SystemLink can also automatically assign and schedule those work items based on resource availability and custom logic.

Product Insights

SystemLink collects and links test results, parametric measurements, TDMS files, uploaded files, and product specifications.

Teams can use this information to search, visualize, and correlate quality data across products and programs.

Data Sources and Supported File Formats
SystemLink ingests data for large-scale analysis through the following means:
  • Live test publishing
  • Multi-language APIs
  • Browser-based file previews
  • ETL pipelines for normalizing file formats
  • Columnar data frames
Analysis and Automation

SystemLink runs published Jupyter notebooks as analysis routines without requiring users to write or modify notebook code.

Users can manually trigger analysis routines. You can also set SystemLink to automatically trigger an analysis routine when a data event occurs or on a recurring schedule.

Access Governance and Deployment
SystemLink enforces data isolation through the following methods:
  • Workspaces and roles
  • Corporate identity providers with OIDC
  • On-premises deployment
  • Cloud deployment

SystemLink Browser Requirements

To access SystemLink, your browser must meet certain requirements.

Your computer must have the latest version of a browser that supports SystemLink:
  • Chrome
  • Firefox
  • Edge (Chromium)
  • Safari

SystemLink Client

The SystemLink Client is a foundational software component that connects individual computers and test systems to a SystemLink Server.

SystemLink Client enables the monitoring, management, and integration of systems into SystemLink services.

You can install the SystemLink Client on the following systems.

  • Test stations
  • Lab computers
  • Measurement systems
  • Validation and production equipment
  • Engineering workstations

Installing SystemLink Client provides visibility and management across an entire fleet of distributed systems. To download SystemLink Client to a system, refer to the download page.

SystemLink Client Requirements

To use SystemLink Client to communicate with targets, your targets must meet the following requirements.

Hardware Requirements

Table 2. Hardware Requirements for Targets Using SystemLink Client
Component Windows NI Linux Real-Time
Processor

Pentium 4 G1 (equivalent or better)

Intel or ARM model

RAM 2 GiB minimum

4 GiB recommended

512 MiB minimum

1+ GiB recommended

Disk 1 GB minimum

2+ GB recommended

512 MB

Software Requirements

For SystemLink Client software requirements, refer to SystemLink Client and External Dependencies Compatibility.

Node Requirements

Table 3. Requirements for a Node Running SystemLink
Component Windows NI Linux Real-Time
OS (64-bit only)
  • Windows 10 (64-bit)
  • Windows 11 (64-bit)

NI Linux Real-Time 2019, 2020, 2021

(Supports LabVIEW RT 2019, 2020, 2021 and NXG 5.0 and later)

Processor 64-bit All Intel and ARM models supported
RAM
  • 2 GiB minimum
  • 4 GiB recommended
  • 512 MiB minimum
  • 1+ GiB recommended
Disk
  • 1 GB minimum
  • 2+ GB recommended
512 MB recommended
Note SystemLink does not support VxWorks or Phar Lap OS.

Storing and Forwarding Test Data

Use the SystemLink Test Monitor Client to avoid data loss during network disruptions.

A test system using the SystemLink Test Monitor Client requires a stable network connection to SystemLink. If you have an unstable connection, you can configure the Client avoid data loss.

To maintain optimal memory usage and storage availability regardless of losing offline data, use the default configuration of the plug-in.

  1. Open TestStand on the managed system you want to store offline data during network disruptions.
  2. Select Configure » Result Processing.
  3. For NI SystemLink Test Monitor Client, click Options Options button icon (wrench and screwdriver)..
  4. Choose the option that best meets your needs.
    OptionDescription
    Store all test data on the client regardless of connection status, memory consumption, and storage space. Automatically forward this data in batches whenever the client is connected to SystemLink. Check Enable Storing and Forwarding of Test Data and select Always.
    Store test data on the client only when the client is disconnected from SystemLink; for example, during a network interruption. Automatically forward this data to SystemLink when the client reconnects to it. Check Enable Storing and Forwarding of Test Data and select Only When Disconnected From Server.
  5. Click OK.

Viewing and Editing User Account Settings

Use the SystemLink web interface to complete tasks such as modifying the language settings, picking an application color theme, and viewing account information.

  1. In the top-right corner, click User profile icon.Welcome, <User Name> » Account.
  2. In the Edit account slide-out, achieve the following goals.
    Goal Description

    Set the language

    Click the Language drop-down and select from the following languages:
    Note By default, the language selector matches the langauge of the browser.
    • English—English language setting
    • Français—French language setting
    • Deutsch—German language setting
    • 日本語—Japanese language setting
    • 中文—Chinese language setting

    The chosen language determines the decimal separator type and the locale to use for dates.

    Set the color theme

    Click the Theme drop-down and select from the following themes:
    • Light—A theme with light background and UI elements and dark text
    • Dark—A theme with dark background and UI elements and light text
    • Device default—SystemLink matches the default theme of the device or browser
    Note SystemLink remembers the theme preference across browsers. Your chosen theme applies wherever you log in.

    View information on your user account

    View the following account information:
    Note You cannot edit these properties. Your organization provides this information through an identity management system such as Microsoft Azure AD, Okta, or Google Workspace.
    • First name—The first name of the user
    • Last name—The last name of the user
    • Username—The unique identifier SystemLink uses for your account
    • Email—The email address SystemLink sends notifications
    • Phone—The phone number of the user
    Note If any of the account information is incorrect, contact your server administrator or IT support team to request an update.
  3. Click OK.