Creating a DUT
- Updated2026-04-22
- 4 minute(s) read
Create a DUT by configuring the type, name, part number, and input parameters.
To create a DUT, complete the following steps:
- In the PAconfigurator Navigation area, click Devices Under Test.
- Select the Devices Under Test tab.
- In the list area of the Devices Under Test tab, click New Device Under Test.
-
In the New Device Under Test tab, configure the
following settings:
- Enter a Name for the DUT.
- Select a Device Under Test Type and write a description for the DUT.
-
Enter a Part Number for the DUT.
Note You cannot change the part number after you save the DUT. If you upload this DUT to SystemLink, this part number is the part number of the SystemLink product. The PAtools DUT part number must match the part number of the SystemLink product.
-
In DUT Input Parameters, define each input
parameter.
The input parameters available for configuration in the DUT Input Parameters dialog depend on the DUT type that you select.
-
In the Test Input Parameters field, enter a
Default Value for each input parameter.
The input parameters available for configuration in the Test Input Parameters dialog depend on the DUT type that you select. All variables except Default Value are read-only. You cannot delete input parameters from the list. However, you can add input parameters by clicking Add Variable Input Parameter.
If you add input parameters, configure the following settings:- The Defined Variable as defined in or in .
- The Display Name that you see when creating a test.
- The Default Value of the variable.
- The Configuration Rule that determines the minimum and maximum values for the parameter. Alternatively, you can choose from the entries of a user-defined Selection List.
- Click Save.
Versioning DUTs
Create a version of an existing DUT to upload the DUT to SystemLink and improve the traceability of changes to DUT input parameters.
Introduced in PAtools 2025 Q2
- Open the Devices Under Test tab.
-
Select the DUT that you want to version from the list.
The summary page for the DUT appears in a new tab.
- Click Create Version.
- Enter a Description.
-
Click Create.
The summary page of the DUT displays an entry for the new version in the Versions section.
Access the content folder for the versioned DUT in the Development area Device_under_Test_Library. The content folder for the versioned DUT is copied and stored in the same folder as the original DUT. The versioned folder includes the version number at the end of the folder name (for example, <DUTNAME>_1). All links and references in the versioned folder are copies of the original.
When building a test with the Test Wizard, you can select a specific version of a DUT. You can also configure the values of the contained input parameters.
Deleting Versioned DUTs
Delete a version of a DUT from the summary page of the DUT.
- Open the Devices Under Test tab.
-
Select a DUT.
Selecting a DUT opens the summary page of the DUT.
-
In the Versions section, click the trash
icon for the version that you want to delete.
You can delete a version of a DUT that you uploaded to SystemLink. In this case, a window appears with a reminder that the version is linked to SystemLink. Confirm that you want to proceed with the deletion.
Uploading a DUT to SystemLink
Upload a DUT to SystemLink to create a product in SystemLink.
The SystemLink product is added to the SystemLink workspace, as defined in . In SystemLink Configuration, you can enable the ability to upload a DUT to SystemLink. Refer to Configuring PAtools to Interact with SystemLink for more information.
Complete the following steps to upload a DUT to SystemLink as a product:
- Open the Devices Under Test tab in PAtools.
- Open the DUT you want to upload.
-
Click Upload to SystemLink and configure
the following settings:
- Enter a Name for the SystemLink product.
-
Select a Device Under Test
Version.
Note The Part number field automatically populates with the part number that you assigned to the DUT during the initial configuration.
- Click OK.
- Click OK.
The first time you upload a DUT, PAtools creates a SystemLink product. PAtools then creates an association between the SystemLink product and the PAtools DUT. For subsequent uploads, PAtools updates the associated SystemLink product or creates a product if the associated SystemLink product is deleted. The PAtools DUT type and the part number are set as the SystemLink product family and part number, respectively.
In SystemLink, custom fields display the following information:
- DUT Input Parameters
- Test Input Parameters
Related Information
- Configuring PAtools to Interact with SystemLink
Configure PAtools to interact with SystemLink so that PAtools can send information to SystemLink.