This document contains the Static Test Software Suite known issues that were discovered before and since the release of Static Test Software Suite 1.2. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1720581 |
Modifications to Graph Properties in Static Data Viewer Graphs are Not SavedStatic Data Viewer allows you to change graph properties, such as line plot color and style, using the graph legend. Any changes made are not saved when a graph is saved. If a graph is closed and re-opened all changes are lost. Auto-scale and max/min scale properties are saved.
Workaround: There is currently no known workaround for this issue.
|
Reported Version: Static Test Software Suite: 1.1 Resolved Version: N/A Added: Dec 2, 2021 |
|
Static Data Viewer Channel or Graph Names Containing Backslashes (\) are Displayed Incorrectly in List ViewsChannel or graph names with a backslash (\) result in unexpected sub-hierarchies in list tree views. List tree views are currently used in the Saved Graphs and Saved Alarms list views. Workaround: Avoid the use of backslashes in channel and graph names.
|
Reported Version: Static Test Software Suite: 1.1 Resolved Version: N/A Added: Dec 2, 2021 |
||
1723638 |
Loss of Connection with a Network Chassis Not Reflected in FlexLogger but Logging of Channel Data is StoppedIf a network device loses connection there may be no indication within FlexLogger that connection was lost. However, when a network device loses connection all channel data logging associated with the device is stopped. The loss of data can be observed in the log files. Opening MAX and clicking on the device will cause a refresh of state information which will result in an error appearing in FlexLogger.
Workaround: There is currently no known workaround for this issue.
|
Reported Version: Static Test Software Suite: 1.1 Resolved Version: N/A Added: Dec 2, 2021 |
|
1720610 |
TSN-capable Devices Temporarily Lose Synchronization Control During Long Duration TestsIn longer test runs (hours to days) with high channel counts (>100), temporary loss of synchronization control between TSN-capable devices has been observed. In these situations, the clocks on TSN-capable devices will drift over time until synchronization is restored. Depending on the amount of drift and the length of time of the control loss, the synchronization constraints may or may not have been violated. In FlexLogger, the synchronization loss is displayed with a red "SYNC" indicator. FlexLogger annotates the log file with timestamped sync loss messages listing when each channel loses synchronization. It also annotates when synchronization is restored.
Workaround: There is currently no known workaround for this issue. Messages in the log files can be used to determine periods of synchronization loss.
|
Reported Version: Static Test Software Suite: 1.1 Resolved Version: N/A Added: Dec 2, 2021 |
|
1720599 |
Static Data Viewer Does Not Immediately Display Triggered AlarmsWhen multiple alarm rules (>10) are enabled within short period of time, triggered alarms that occur shortly after enabling may not appear in the Static Data Viewer right away. It can sometimes take minutes for alarms to appear, however the timestamps on the triggered alarms are correct. The behavior is no longer present after the alarms have been enabled for several minutes. Workaround: Enable all alarms several minutes before any test run to ensure triggered alarms will be immediately visible in the Static Data Viewer.
|
Reported Version: Static Test Software Suite: 1.1 Resolved Version: N/A Added: Dec 2, 2021 |
|
2182373 |
Annotation for Static Data Viewer Plug-in fails to load in FlexLogger 2022 Q4 and newerWhen configuring FlexLogger for Static Data Viewer using FlexLogger 2022 Q4 or later, attempting to add a channel with the Annotation for Static Data Viewer Plug-in results in two error messages in FlexLogger. The plugin is necessary to annotate the FlexLogger log file with comments and alarms from the Static Data Viewer. The Static Data Viewer can still be used to view and graph data, as well as set and view alarms; however, the alarms and any added notes will no longer be included in the FlexLogger log file. Delete the Annotation For Static Data Viewer Plug-in from the channel list to remove the errors in FlexLogger.
Workaround: Install FlexLogger 2021 R4.
|
Reported Version: Static Test Software Suite 1.2 Resolved Version: N/A Added: Nov 17, 2022 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.
Explore Support Content and Product Documentation
Ask the NI Community
Request Support from an Engineer
A valid service agreement may be required, and support options vary by country