This document contains the LabVIEW PDM Acquisition Toolkit known issues that were discovered before and since the release of LabVIEW PDM Acquisition Toolkit 2021 Q4. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1374124 |
PDM Acquisition Toolkit 2021 Q2 Does Not Work with Volume License ManagerIn Volume License Manager (VLM) 3.3, creating a volume license installer with the PDM Acquisition Toolkit results in an unexpected error and no further error information is provided.
Workaround: There is currently no known workaround for this issue.
|
Reported Version: LabVIEW PDM Acquisition Toolkit 2021 Q2 Resolved Version: N/A Added: Apr 6, 2021 |
|
1383057 |
Silence Output Mode Does Not Work Pre-TriggerIn the Configure Idle Output Mode VI, when idle mode is Silence and the generation task is set to wait for a trigger, the PDM output task is fixed at Logic Level Low (PDM output = -1) before the trigger occurs instead of Silence (PDM output = 0).
Workaround: There is currently no known workaround for this issue.
|
Reported Version: LabVIEW PDM Acquisition Toolkit 2021 Q2 Resolved Version: N/A Added: Apr 6, 2021 |
|
1751119 |
No Error Returns When Multiple Acquisition or Generation Tasks Are ConfiguredIf more than two
tasks are configured, LabVIEW will not report an error (i.e. error 511) when
executing the code. In some cases, the code executes with an unsupported
configuration. For example, if more than two tasks on one device are used for
I2S acquisition and the device is set to master for the clock mode, the clock
generated for one of those tasks could output a rate that does not match the
specified clock rate.
Workaround: The PDM Acquisition Toolkit does not support configuring more than two acquisition or generation tasks per device. Update the code to not use more than two tasks.
|
Reported Version: LabVIEW PDM Acquisition Toolkit 2021 Q4 Resolved Version: N/A Added: Dec 7, 2021 |
|
1757018 |
Broken Run Arrow for All Examples in LabVIEW 2018 SP1The Run button
appears broken for all LabVIEW PDM Acquisition Toolkit examples when using
LabVIEW 2018 Service Pack 1 (SP1).
Workaround: Recompile the example by pressing <Ctrl-Shift-Run button>.
|
Reported Version: LabVIEW PDM Acquisition Toolkit 2021 Q4 Resolved Version: N/A Added: Dec 7, 2021 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.
Explore Support Content and Product Documentation
Ask the NI Community
Request Support from an Engineer
A valid service agreement may be required, and support options vary by country