NI Vision Acquisition Software 20.0 Known Issues

Overview

This document contains the NI Vision Acquisition Software known issues that were discovered before and since the release of NI Vision Acquisition Software 20.0. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.

 

Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.

Bug Number

Legacy ID

Description

Details

197812 722200

Plug and Play Event for NI-IMAQdx does not work correctly.

Plug and Play Event for NI-IMAQdx does not work correctly.

Workaround:

Use the "IMAQdx Enumerate Cameras.VI" to check if a camera is still detected.

Reported Version:

NI-IMAQdx 18.5

Resolved Version:

N/A

Added:

Aug 19, 2019

197718 691432

It is possible in some cases to get a "Camera already in use" error when first opening a session to the a Camera Link board through NI-IMAQdx.

It is possible in some cases to get a "Camera already in use" error when first opening a session to the a Camera Link board through NI-IMAQdx.

Workaround:

Disable and then re-enable the card  in Device Manager.

Reported Version:

NI-IMAQ 18.0

Resolved Version:

N/A

Added:

May 21, 2018

197750 708625

Changing the source of a Camera Link camera control line doesn't take effect until the session is closed and reopened.

Changing the source of a Camera Link camera control line doesn't take effect until the session is closed and reopened.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

NI-IMAQdx 18.5

Resolved Version:

N/A

Added:

Aug 20, 2018

197767 730702

Using sequence on Linux RT ISC-178x can cause a memory leak over time.

Using sequence on Linux RT ISC-178x can cause a memory leak over time.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

NI-IMAQdx 18.5

Resolved Version:

N/A

Added:

Aug 19, 2019

431564 591562

Upgrading and then Downgrading NI-IMAQdx may not yield correct version.

Upgrading and then downgrading the NI-IMAQdx driver might not revert back completely to the correct version.

Workaround:

Manually delete the niimaqdx.dll from System 32 and SysWOW64 after uninstalling the new version and then force reinstall the old one.

Reported Version:

NI-IMAQdx 15.5

Resolved Version:

N/A

Added:

May 21, 2018

457008 427019

Only one NI PCIe-1473R framegrabber can use the virtual serial port at a time.

Only one NI PCIe-1473R framegrabber can use the virtual serial port at a time.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

NI-IMAQ I/O 2.8

Resolved Version:

N/A

Added:

Feb 14, 2014

457477 714802

In the Triggered Grab example, the Timeout input is overwritten by the default five second timeout of the Grab2.vi.

In the Triggered Grab example, the Timeout input is overwritten by the default five second timeout of the Grab2.vi.

Workaround:

In order to use the Timeout property, wire a -2 as the timeout input of the Grab2.vi

Reported Version:

NI-IMAQdx 18.0

Resolved Version:

N/A

Added:

Aug 20, 2018

456952 699992

When acquiring from the Windows ISC-178x Smart Cameras, it is possible to see a high CPU utilization.

This is due to limited CPU resources on the device.

Workaround:

Disabling image display should help reduce the utilization.

Reported Version:

NI-IMAQdx 18.0

Resolved Version:

N/A

Added:

Aug 20, 2018

457510 474860

Renaming a camera on some real-time targets may take a long time to complete.

Renaming a camera on some real-time targets may take a long time to complete.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

Vision Acquisition Software Unknown

Resolved Version:

N/A

Added:

Aug 19, 2013

458113 657951

Migrating the Vision Acquisition Express VI from LabVIEW to LabVIEW NXG will return a broken VI.

Migrating the Vision Acquisition Express VI from LabVIEW to LabVIEW NXG will return a broken VI.

Workaround:

After the migration replace the property node that is returned as unavailable with a random number generator to get a unique name.

Reported Version:

NI-IMAQdx 17.5

Resolved Version:

N/A

Added:

May 20, 2019

458865 690945

If selecting a camera file in NI-MAX results in an error, there will be no way to switch to a different camera file.

If selecting a camera file in NI-MAX results in an error, there will be no way to switch to a different camera file.

Workaround:

Either delete the IMAQ .iid file on disk or change the .icd file it points to.

Reported Version:

NI-IMAQdx 18.0

Resolved Version:

N/A

Added:

May 21, 2018

458573 727734

Building a LabVIEW installer from the PCIe-1473R example does not auto-select IMAQ I/O runtime as a dependency.

Building a LabVIEW installer from the PCIe-1473R example does not auto-select IMAQ I/O runtime as a dependency.

Workaround:

Turn off the auto-select option and manually select IMAQ I/O Run-Time, or install the runtime seperately on the deployed system.

Reported Version:

NI-IMAQ I/O 19.0

Resolved Version:

N/A

Added:

May 20, 2019

457814 682085

AXIS Q1765-LE cameras are not enumerated in NI-MAX on Windows 10 computers.

AXIS Q1765-LE cameras are not enumerated in NI-MAX on Windows 10 computers.

Workaround:

Use a Windows 7 computer and port over the generated .icd and .iid files (located under C:\Users\Public\Documents\National Instruments\NI-IMAQdx\Data) of the camera to the Windows 10 computer.

Reported Version:

NI-IMAQdx 17.1

Resolved Version:

N/A

Added:

May 21, 2018

458864 690944

After renaming a Camera Link board in NI-MAX, you must close and re-open MAX before it will show up again.

After renaming a Camera Link board in NI-MAX, you must close and re-open MAX before it will show up again.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

NI-IMAQdx 18.0

Resolved Version:

N/A

Added:

Aug 18, 2018

458869 705508

When a GigE camera has a UserDefinedName with a special character in it, the .iid file is not created properly.

When a GigE camera has a UserDefinedName with a special character ('\"', '*', '/', ':', '<', '>', '?', '\\', '|') in it, the .iid file is not created properly.

Workaround:

Removing the character or manually creating the .iid file on disk and pointing to the serial number of the camera.

Reported Version:

NI-IMAQdx 17.5

Resolved Version:

N/A

Added:

Aug 18, 2018

197817

clsernif_ReadSerialPort and clsernif_WriteSerialPort cannot be executed simultaneously with the PCIe-1477.

clsernif_ReadSerialPort and clsernif_WriteSerialPort cannot be executed simultaneously with the PCIe-1477.

Workaround:

Call clsernif_ReadSerialPort and clsernif_WriteSerialPort sequentially

Reported Version:

NI-IMAQ I/O 18.5

Resolved Version:

N/A

Added:

Oct 18, 2019

Final Time Issue Listed

Issues found in this section will not be listed in future known issues documents for this product.

There are currently no issues to list.

Additional Resources

Explore Support Content and Product Documentation 

 

 

Ask the NI Community

 

 

Request Support from an Engineer

 

A valid service agreement may be required, and support options vary by country

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).