This document contains the LabVIEW NXG Web Module known issues that were discovered before and since the release of LabVIEW NXG 5.1 Web Module. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
52478 | 676137 |
Clicking and dragging to select multiple items within a cluster on the front panel failsWorkaround: Manually select the items within the cluster while holding Shift |
Reported Version: LabVIEW NXG Web Module 2.1 Resolved Version: N/A Added: Apr 27, 2020 |
52440 | 666046 |
Radio Button Group does not resize when additional Radio Buttons are addedWorkaround: There is currently no known workaround for this issue. |
Reported Version: LabVIEW NXG Web Module 2.0 Resolved Version: N/A Added: Apr 27, 2020 |
52689 | 666287 |
Warning when copying a Graph from a VI's Diagram to a Web VI's DiagramWhen you copy a VI's Diagram contents and paste them on a Web VI's Diagram, a warning will appear if one of the items is a Graph indicator. Workaround: Delete the graph terminal and create a new Graph in the Web VI |
Reported Version: LabVIEW NXG Web Module 2.0 Resolved Version: N/A Added: Apr 27, 2020 |
53292 | 664268 |
VI snippets do not create controls on the Panel when placed in a Web VIWorkaround: There is currently no known workaround for this issue. |
Reported Version: LabVIEW NXG Web Module 2.0 Resolved Version: N/A Added: Apr 27, 2020 |
53313 | 667006 |
Internal errors occur when calling a Web VI with a subVI that has an output inside of a Disable StructureWorkaround: There is currently no known workaround for this issue. |
Reported Version: LabVIEW NXG Web Module 2.1 Resolved Version: N/A Added: Apr 27, 2020 |
53315 | 669019 |
FormatDateTimeString function does not handle dates past 2038 correctly.Workaround: There is currently no known workaround for this issue. |
Reported Version: LabVIEW NXG Web Module 2.0 Resolved Version: N/A Added: Apr 27, 2020 |
68282 | 719781 |
JSLI dependencies can't be located after changing their namespace in the project.Workaround: There is currently no known workaround for this issue. |
Reported Version: LabVIEW NXG Web Module 3.1 Resolved Version: N/A Added: May 17, 2020 |
146947 | 736938 |
Can't change value of control with duplicate terminals from the PanelA control with a duplicate terminal on the Diagram can't have its value changed from the Panel. Workaround: Right-click the duplicate terminal on the Diagram >> Change to read. |
Reported Version: LabVIEW NXG Web Module 3.2 Resolved Version: N/A Added: May 17, 2020 |
352961 | 673324 |
Adding items to the FrontPanelCanvas <section> tags in the HTML panel always places the new items at the top of the sectionBecause the items that are added are always at the top of the section, the content that is added will always appear behind the content that LabVIEW NXG creates Workaround: Set the z-index property for the item that is being added |
Reported Version: LabVIEW NXG Web Module 2.0 Resolved Version: N/A Added: Apr 27, 2020 |
358872 | 667774 |
The Output tab does not allow horizontal scrollingWorkaround: Copy the text from the Output tab into another location and read the message there |
Reported Version: LabVIEW NXG Web Module 2.0 Resolved Version: N/A Added: Apr 27, 2020 |
358881 | 669020 |
String to Number functions may return incorrect values when converting to I64 or U64 data types in Web VIsWhen converting from strings to 64-bit numbers, the String to Number functions (Decimal String to Number, Hex String to Number, etc.) can return unexpected results Workaround: There is currently no known workaround for this issue. |
Reported Version: LabVIEW NXG Web Module 2.0 Resolved Version: N/A Added: Apr 27, 2020 |
358851 | 666182 |
When attempting to create a sub VI from code on a Web VI, you can only create a sub Web VIWorkaround: There is currently no known workaround for this issue. |
Reported Version: LabVIEW NXG Web Module 2.0 Resolved Version: N/A Added: Apr 27, 2020 |
352925 | 666581 |
Dragging multiple arrays into a tab control can cause visual issuesWorkaround: Save the Web VI and reopen it, or drag a single element into the tab at a time |
Reported Version: LabVIEW NXG Web Module 2.0 Resolved Version: N/A Added: Apr 27, 2020 |
1172217 |
NXG Web VI Chart creates unwanted plots when color is changed via property nodeWhen using LabVIEW NXG Web Module bar chart, if you create a chart property node in the block diagram for the plots, the front panel bar chart will automatically create an unwanted plot line. Workaround: Do not use the color property node. Instead, set the color by clicking on the chart and clicking the gear icon in the Item tab for the plot. |
Reported Version: LabVIEW NXG Web Module 5.0 Resolved Version: N/A Added: Dec 8, 2020 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.