Table Of Contents

Open (AMQP Sync)

Version:
Last Modified: November 14, 2019

Creates a synchronous message session with the server based on the SystemLink configuration information.

Messages received through the session are queued internally until the queue is full. After the queue is full, the queue no longer accepts new messages until you read messages from the queue or increase the message queue size. You can perform message handling with synchronous read operations.

spd-note-note
Note  

SystemLink Cloud does not support this VI.

configuration

AMQP connection to the server.

If you leave this input unwired, this VI uses the default connection. It automatically retrieves your SystemLink Server credentials when you execute the application on a managed system or on the server.

error in

Error conditions that occur before this VI runs. The VI responds to this input according to standard error behavior.

message session

Synchronous message session created with the server.

error out

Error information. This VI produces this output according to standard error behavior.