Classes

NameDescription
RFmxCdma2kMX

Defines a root class which is used to identify and control CDMA2k signal configuration.

RFmxCdma2kMXAcp

Represents the ACP measurement.

RFmxCdma2kMXAcpConfiguration

Provides methods to configure the ACP measurement.

RFmxCdma2kMXAcpResults

Provides methods to fetch and read the ACP measurement results.

RFmxCdma2kMXCda

Represents the CDA measurement.

RFmxCdma2kMXCdaConfiguration

Provides methods to configure the CDA measurement.

RFmxCdma2kMXCdaResults

Provides methods to fetch and read the CDA measurement results.

RFmxCdma2kMXChp

Represents the CHP measurement.

RFmxCdma2kMXChpConfiguration

Provides methods to configure the CHP measurement.

RFmxCdma2kMXChpResults

Provides methods to fetch and read the CHP measurement results.

RFmxCdma2kMXConstants

Specifies constants for I/O terminals.

RFmxCdma2kMXModAcc

Represents the ModAcc measurement.

RFmxCdma2kMXModAccConfiguration

Provides methods to configure the ModAcc measurement.

RFmxCdma2kMXModAccResults

Provides methods to fetch and read the ModAcc measurement results.

RFmxCdma2kMXObw

Represents the OBW measurement.

RFmxCdma2kMXObwConfiguration

Provides methods to configure the OBW measurement.

RFmxCdma2kMXObwResults

Provides methods to fetch and read the OBW measurement results.

RFmxCdma2kMXQevm

Represents the QEVM measurement.

RFmxCdma2kMXQevmConfiguration

Provides methods to configure the QEVM measurement.

RFmxCdma2kMXQevmResults

Provides methods to fetch and read the QEVM measurement results.

RFmxCdma2kMXSem

Represents the SEM measurement.

RFmxCdma2kMXSemConfiguration

Provides methods to configure the SEM measurement.

RFmxCdma2kMXSemResults

Provides methods to fetch and read the SEM measurement results.

RFmxCdma2kMXSlotPhase

Represents the SlotPhase measurement.

RFmxCdma2kMXSlotPhaseConfiguration

Provides methods to configure the SlotPhase measurement.

RFmxCdma2kMXSlotPhaseResults

Provides methods to fetch and read the SlotPhase measurement results.

RFmxCdma2kMXSlotPower

Represents the SlotPower measurement.

RFmxCdma2kMXSlotPowerConfiguration

Provides methods to configure the SlotPower measurement.

RFmxCdma2kMXSlotPowerResults

Provides methods to fetch and read the SlotPower measurement results.

RFmxCdma2kMXSubObject

Represents members that are common to all sub-object of RFmxCdma2kMX classes.

Interfaces

None

Structures

None

Enumerations

NameDescription
RFmxCdma2kMXAcpAveragingEnabled

Specifies whether to enable averaging for the ACP measurement.

RFmxCdma2kMXAcpAveragingType

Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for ACP measurement.

RFmxCdma2kMXAcpFftOverlapMode

Specifies how the FFT overlap is applied to the acquired samples. The default Value is Disabled.

RFmxCdma2kMXAcpIFOutputPowerOffsetAuto

Specifies whether the measurement computes an IF output power level offset for the offset channels to improve the dynamic range of the ACP measurement. This method is used only if you set the SetMeasurementMethod(string, RFmxCdma2kMXAcpMeasurementMethod) method to DynamicRange.

RFmxCdma2kMXAcpMeasurementMethod

Specifies the method for performing the ACP measurement.

RFmxCdma2kMXAcpNoiseCompensationEnabled

Specifies whether to enable compensation of the channel powers for the inherent noise floor of the signal analyzer.

RFmxCdma2kMXAcpRbwAutoBandwidth

Specifies whether the measurement computes the RBW.

RFmxCdma2kMXAcpRbwFilterType

Specifies the shape of the digital RBW filter.

RFmxCdma2kMXAcpSweepTimeAuto

Specifies whether the measurement computes the sweep time.

RFmxCdma2kMXBranch

Specifies the branch on which a specific user-defined channel is mapped. This method is used only when you set the SetChannelConfigurationMode(string, RFmxCdma2kMXChannelConfigurationMode) method to UserDefined.Use "channel(n)" as the Selector Strings to configure or read this method.

RFmxCdma2kMXCdaIQGainImbalanceRemovalEnabled

Specifies whether to remove the I/Q gain imbalance before the code domain analysis (CDA) measurement.

RFmxCdma2kMXCdaIQOffsetRemovalEnabled

Specifies whether to remove I/Q offset before the code domain analysis (CDA) measurement.

RFmxCdma2kMXCdaIQQuadratureErrorRemovalEnabled

Specifies whether to remove the I/Q quadrature error before the code domain analysis (CDA) measurement.

RFmxCdma2kMXCdaMeasurementChannelBranch

Specifies the branch of a channel subject to channel specific analysis.

RFmxCdma2kMXCdaPowerUnit

Specifies the measurement unit of the measured code domain power results.

RFmxCdma2kMXCdaReceiveFilterEnabled

Specifies whether to enable the received filter for the code domain analysis (CDA) measurement. Use this method to disable the filter, if the received signal is already filtered.

RFmxCdma2kMXCdaSpectrumInverted

Specifies whether the spectrum of the signal is inverted.

RFmxCdma2kMXCdaSynchronizationMode

Specifies whether the measurement is performed from the frame, slot, or symbol boundary.

RFmxCdma2kMXChannelConfigurationMode

Specifies whether to detect the channels automatically or to use a specified channel configuration.

RFmxCdma2kMXChpAveragingEnabled

Specifies whether to enable averaging for the CHP measurement.

RFmxCdma2kMXChpAveragingType

Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the CHP measurement.

RFmxCdma2kMXChpRbwAutoBandwidth

Specifies whether the measurement computes the RBW.

RFmxCdma2kMXChpRbwFilterType

Specifies the shape of the digital RBW filter.

RFmxCdma2kMXChpSweepTimeAuto

Specifies whether the measurement computes the sweep time.

RFmxCdma2kMXDigitalEdgeTriggerEdge

Specifies the active edge for the trigger. This method is used only when you set the SetTriggerType(string, RFmxCdma2kMXTriggerType) method to DigitalEdge.

RFmxCdma2kMXIQPowerEdgeTriggerLevelType

Specifies the reference for the IQ Power Edge Level Type method. This method is used only when you set the SetTriggerType(string, RFmxCdma2kMXTriggerType) method to IQPowerEdge.

RFmxCdma2kMXIQPowerEdgeTriggerSlope

Specifies whether the device asserts the trigger when the signal power is rising or when it is falling. The device asserts the trigger when the signal power exceeds the specified level with the slope you specify. This method is used only when you set the SetTriggerType(string, RFmxCdma2kMXTriggerType) method to IQPowerEdge.

RFmxCdma2kMXLimitedConfigurationChange

Specifies the set of properties that are considered by RFmx in the locked signal configuration state.

RFmxCdma2kMXLinkDirection

Specifies the direction for which the frequency is calculated. Only Uplink is supported.

RFmxCdma2kMXMeasurementTypes

Specifies the type of measurement.

RFmxCdma2kMXModAccDetectedBranch

Returns the branch of the detected channel. If you set the SetChannelConfigurationMode(string, RFmxCdma2kMXChannelConfigurationMode) method to UserDefined, the method returns the branch of the configured channel.Use "channel(n)" as the Selector Strings to read this method.

RFmxCdma2kMXModAccIQGainImbalanceRemovalEnabled

Specifies whether to remove the I/Q gain imbalance before an EVM measurement.

RFmxCdma2kMXModAccIQOffsetRemovalEnabled

Specifies whether to remove the I/Q offset before an EVM measurement.

RFmxCdma2kMXModAccIQQuadratureErrorRemovalEnabled

Specifies whether to remove the I/Q quadrature error before an EVM measurement.

RFmxCdma2kMXModAccMultiCarrierFilterEnabled

Specifies whether to enable the multi carrier filter which can be used to improve ModAcc measurement quality in presence of neighboring carriers.

RFmxCdma2kMXModAccPeakActiveCdeBranch

Returns the branch of the channel corresponding to the value that the GetPeakActiveCde(string, out double) method returns.

RFmxCdma2kMXModAccPeakCdeBranch

Returns the branch corresponding to the value that the GetPeakCde(string, out double) method returns.

RFmxCdma2kMXModAccReceiveFilterEnabled

Specifies whether to enable the received filter for the ModAcc measurement.

RFmxCdma2kMXModAccSpectrumInverted

Specifies whether the spectrum of the signal is inverted.

RFmxCdma2kMXModAccSynchronizationMode

Specifies whether the measurement is performed from the frame, slot, or symbol boundary.

RFmxCdma2kMXObwAveragingEnabled

Specifies whether to enable averaging for the OBW measurement.

RFmxCdma2kMXObwAveragingType

Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the OBW measurement.

RFmxCdma2kMXObwRbwAutoBandwidth

Specifies whether the measurement computes the RBW.

RFmxCdma2kMXObwRbwFilterType

Specifies the shape of the digital RBW filter.

RFmxCdma2kMXObwSweepTimeAuto

Specifies whether the measurement computes the sweep time.

RFmxCdma2kMXPropertyId

Specifies all the attribute identifiers.

RFmxCdma2kMXQevmAveragingEnabled

Specifies whether to enable averaging for the QEVM measurement.

RFmxCdma2kMXQevmIQGainImbalanceRemovalEnabled

Specifies whether to remove I/Q gain imbalance before QEVM measurement.

RFmxCdma2kMXQevmIQOffsetRemovalEnabled

Specifies whether to remove I/Q offset before QEVM measurement.

RFmxCdma2kMXQevmIQQuadratureErrorRemovalEnabled

Specifies whether to remove I/Q quadrature error before QEVM measurement.

RFmxCdma2kMXQevmReceiveFilterEnabled

Specifies whether to enable the received filter for the QEVM measurement.

RFmxCdma2kMXQevmSpectrumInverted

Specifies whether the spectrum of the signal is inverted.

RFmxCdma2kMXRadioConfiguration

Specifies the radio configuration for the channel.

RFmxCdma2kMXSemAveragingEnabled

Specifies whether to enable averaging for the SEM measurement.

RFmxCdma2kMXSemAveragingType

Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the SEM measurement.

RFmxCdma2kMXSemLowerOffsetMeasurementStatus

Indicates the lower offset segment measurement status based on measurement limits specified by the standard.Use "offset(n)" as the Selector Strings to read this result.

RFmxCdma2kMXSemMeasurementStatus

Indicates the overall measurement status based on the measurement limits, which are specified by the standard for each offset segment.

RFmxCdma2kMXSemOffsetRbwFilterType

Returns the type of RBW filter used to sweep the offset segment.

RFmxCdma2kMXSemSweepTimeAuto

Specifies whether the measurement computes the sweep time.

RFmxCdma2kMXSemUpperOffsetMeasurementStatus

Indicates the upper offset measurement status based on measurement limits set by the standard.Use "offset(n)" as the Selector Strings to read this result.

RFmxCdma2kMXSlotPhaseReceiveFilterEnabled

Specifies whether to enable the received filter for the SlotPhase measurement. Use this method to disable the filter, if the received signal is already filtered. Specifies whether to enable the received filter for the SlotPhase measurement. Use this method to disable the filter, if the received signal is already filtered.

RFmxCdma2kMXSlotPhaseSpectrumInverted

Specifies whether the spectrum of the signal is inverted.

RFmxCdma2kMXSlotPhaseSynchronizationMode

Specifies whether the measurement is performed from the frame or slot boundary.

RFmxCdma2kMXSlotPowerReceiveFilterEnabled

Specifies whether to enable the received filter for the SlotPower measurement. Use this method to disable the filter, if the received signal is already filtered.

RFmxCdma2kMXSlotPowerSpectrumInverted

Specifies whether the spectrum of the signal is inverted.

RFmxCdma2kMXSlotPowerSynchronizationMode

Specifies whether the measurement is performed from the frame or slot boundary.

RFmxCdma2kMXTriggerMinimumQuietTimeMode

Specifies whether the measurement computes the minimum quiet time used for triggering.

RFmxCdma2kMXTriggerType

Specifies the trigger type.

Delegates

None