NationalInstruments.RFmx.Cdma2kMX
- Updated2025-04-08
- 6 minute(s) read
Classes
Name | Description |
---|---|
RFmxCdma2kMX | Defines a root class which is used to identify and control CDMA2k signal configuration. |
RFmxCdma2kMXAcp | Represents the ACP measurement. |
RFmxCdma2kMXAcpConfiguration | Provides methods to configure the ACP measurement. |
RFmxCdma2kMXAcpResults | Provides methods to fetch and read the ACP measurement results. |
RFmxCdma2kMXCda | Represents the CDA measurement. |
RFmxCdma2kMXCdaConfiguration | Provides methods to configure the CDA measurement. |
RFmxCdma2kMXCdaResults | Provides methods to fetch and read the CDA measurement results. |
RFmxCdma2kMXChp | Represents the CHP measurement. |
RFmxCdma2kMXChpConfiguration | Provides methods to configure the CHP measurement. |
RFmxCdma2kMXChpResults | Provides methods to fetch and read the CHP measurement results. |
RFmxCdma2kMXConstants | Specifies constants for I/O terminals. |
RFmxCdma2kMXModAcc | Represents the ModAcc measurement. |
RFmxCdma2kMXModAccConfiguration | Provides methods to configure the ModAcc measurement. |
RFmxCdma2kMXModAccResults | Provides methods to fetch and read the ModAcc measurement results. |
RFmxCdma2kMXObw | Represents the OBW measurement. |
RFmxCdma2kMXObwConfiguration | Provides methods to configure the OBW measurement. |
RFmxCdma2kMXObwResults | Provides methods to fetch and read the OBW measurement results. |
RFmxCdma2kMXQevm | Represents the QEVM measurement. |
RFmxCdma2kMXQevmConfiguration | Provides methods to configure the QEVM measurement. |
RFmxCdma2kMXQevmResults | Provides methods to fetch and read the QEVM measurement results. |
RFmxCdma2kMXSem | Represents the SEM measurement. |
RFmxCdma2kMXSemConfiguration | Provides methods to configure the SEM measurement. |
RFmxCdma2kMXSemResults | Provides methods to fetch and read the SEM measurement results. |
RFmxCdma2kMXSlotPhase | Represents the SlotPhase measurement. |
RFmxCdma2kMXSlotPhaseConfiguration | Provides methods to configure the SlotPhase measurement. |
RFmxCdma2kMXSlotPhaseResults | Provides methods to fetch and read the SlotPhase measurement results. |
RFmxCdma2kMXSlotPower | Represents the SlotPower measurement. |
RFmxCdma2kMXSlotPowerConfiguration | Provides methods to configure the SlotPower measurement. |
RFmxCdma2kMXSlotPowerResults | Provides methods to fetch and read the SlotPower measurement results. |
RFmxCdma2kMXSubObject | Represents members that are common to all sub-object of RFmxCdma2kMX classes. |
Interfaces
None
Structures
None
Enumerations
Name | Description |
---|---|
RFmxCdma2kMXAcpAveragingEnabled | Specifies whether to enable averaging for the ACP measurement. |
RFmxCdma2kMXAcpAveragingType | Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for ACP measurement. |
RFmxCdma2kMXAcpFftOverlapMode | Specifies how the FFT overlap is applied to the acquired samples. The default Value is Disabled. |
RFmxCdma2kMXAcpIFOutputPowerOffsetAuto | Specifies whether the measurement computes an IF output power level offset for the offset channels to improve the dynamic range of the ACP measurement. This method is used only if you set the SetMeasurementMethod(string, RFmxCdma2kMXAcpMeasurementMethod) method to DynamicRange. |
RFmxCdma2kMXAcpMeasurementMethod | Specifies the method for performing the ACP measurement. |
RFmxCdma2kMXAcpNoiseCompensationEnabled | Specifies whether to enable compensation of the channel powers for the inherent noise floor of the signal analyzer. |
RFmxCdma2kMXAcpRbwAutoBandwidth | Specifies whether the measurement computes the RBW. |
RFmxCdma2kMXAcpRbwFilterType | Specifies the shape of the digital RBW filter. |
RFmxCdma2kMXAcpSweepTimeAuto | Specifies whether the measurement computes the sweep time. |
RFmxCdma2kMXBranch | Specifies the branch on which a specific user-defined channel is mapped. This method is used only when you set the SetChannelConfigurationMode(string, RFmxCdma2kMXChannelConfigurationMode) method to UserDefined.Use "channel(n)" as the Selector Strings to configure or read this method. |
RFmxCdma2kMXCdaIQGainImbalanceRemovalEnabled | Specifies whether to remove the I/Q gain imbalance before the code domain analysis (CDA) measurement. |
RFmxCdma2kMXCdaIQOffsetRemovalEnabled | Specifies whether to remove I/Q offset before the code domain analysis (CDA) measurement. |
RFmxCdma2kMXCdaIQQuadratureErrorRemovalEnabled | Specifies whether to remove the I/Q quadrature error before the code domain analysis (CDA) measurement. |
RFmxCdma2kMXCdaMeasurementChannelBranch | Specifies the branch of a channel subject to channel specific analysis. |
RFmxCdma2kMXCdaPowerUnit | Specifies the measurement unit of the measured code domain power results. |
RFmxCdma2kMXCdaReceiveFilterEnabled | Specifies whether to enable the received filter for the code domain analysis (CDA) measurement. Use this method to disable the filter, if the received signal is already filtered. |
RFmxCdma2kMXCdaSpectrumInverted | Specifies whether the spectrum of the signal is inverted. |
RFmxCdma2kMXCdaSynchronizationMode | Specifies whether the measurement is performed from the frame, slot, or symbol boundary. |
RFmxCdma2kMXChannelConfigurationMode | Specifies whether to detect the channels automatically or to use a specified channel configuration. |
RFmxCdma2kMXChpAveragingEnabled | Specifies whether to enable averaging for the CHP measurement. |
RFmxCdma2kMXChpAveragingType | Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the CHP measurement. |
RFmxCdma2kMXChpRbwAutoBandwidth | Specifies whether the measurement computes the RBW. |
RFmxCdma2kMXChpRbwFilterType | Specifies the shape of the digital RBW filter. |
RFmxCdma2kMXChpSweepTimeAuto | Specifies whether the measurement computes the sweep time. |
RFmxCdma2kMXDigitalEdgeTriggerEdge | Specifies the active edge for the trigger. This method is used only when you set the SetTriggerType(string, RFmxCdma2kMXTriggerType) method to DigitalEdge. |
RFmxCdma2kMXIQPowerEdgeTriggerLevelType | Specifies the reference for the IQ Power Edge Level Type method. This method is used only when you set the SetTriggerType(string, RFmxCdma2kMXTriggerType) method to IQPowerEdge. |
RFmxCdma2kMXIQPowerEdgeTriggerSlope | Specifies whether the device asserts the trigger when the signal power is rising or when it is falling. The device asserts the trigger when the signal power exceeds the specified level with the slope you specify. This method is used only when you set the SetTriggerType(string, RFmxCdma2kMXTriggerType) method to IQPowerEdge. |
RFmxCdma2kMXLimitedConfigurationChange | Specifies the set of properties that are considered by RFmx in the locked signal configuration state. |
RFmxCdma2kMXLinkDirection | Specifies the direction for which the frequency is calculated. Only Uplink is supported. |
RFmxCdma2kMXMeasurementTypes | Specifies the type of measurement. |
RFmxCdma2kMXModAccDetectedBranch | Returns the branch of the detected channel. If you set the SetChannelConfigurationMode(string, RFmxCdma2kMXChannelConfigurationMode) method to UserDefined, the method returns the branch of the configured channel.Use "channel(n)" as the Selector Strings to read this method. |
RFmxCdma2kMXModAccIQGainImbalanceRemovalEnabled | Specifies whether to remove the I/Q gain imbalance before an EVM measurement. |
RFmxCdma2kMXModAccIQOffsetRemovalEnabled | Specifies whether to remove the I/Q offset before an EVM measurement. |
RFmxCdma2kMXModAccIQQuadratureErrorRemovalEnabled | Specifies whether to remove the I/Q quadrature error before an EVM measurement. |
RFmxCdma2kMXModAccMultiCarrierFilterEnabled | Specifies whether to enable the multi carrier filter which can be used to improve ModAcc measurement quality in presence of neighboring carriers. |
RFmxCdma2kMXModAccPeakActiveCdeBranch | Returns the branch of the channel corresponding to the value that the GetPeakActiveCde(string, out double) method returns. |
RFmxCdma2kMXModAccPeakCdeBranch | Returns the branch corresponding to the value that the GetPeakCde(string, out double) method returns. |
RFmxCdma2kMXModAccReceiveFilterEnabled | Specifies whether to enable the received filter for the ModAcc measurement. |
RFmxCdma2kMXModAccSpectrumInverted | Specifies whether the spectrum of the signal is inverted. |
RFmxCdma2kMXModAccSynchronizationMode | Specifies whether the measurement is performed from the frame, slot, or symbol boundary. |
RFmxCdma2kMXObwAveragingEnabled | Specifies whether to enable averaging for the OBW measurement. |
RFmxCdma2kMXObwAveragingType | Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the OBW measurement. |
RFmxCdma2kMXObwRbwAutoBandwidth | Specifies whether the measurement computes the RBW. |
RFmxCdma2kMXObwRbwFilterType | Specifies the shape of the digital RBW filter. |
RFmxCdma2kMXObwSweepTimeAuto | Specifies whether the measurement computes the sweep time. |
RFmxCdma2kMXPropertyId | Specifies all the attribute identifiers. |
RFmxCdma2kMXQevmAveragingEnabled | Specifies whether to enable averaging for the QEVM measurement. |
RFmxCdma2kMXQevmIQGainImbalanceRemovalEnabled | Specifies whether to remove I/Q gain imbalance before QEVM measurement. |
RFmxCdma2kMXQevmIQOffsetRemovalEnabled | Specifies whether to remove I/Q offset before QEVM measurement. |
RFmxCdma2kMXQevmIQQuadratureErrorRemovalEnabled | Specifies whether to remove I/Q quadrature error before QEVM measurement. |
RFmxCdma2kMXQevmReceiveFilterEnabled | Specifies whether to enable the received filter for the QEVM measurement. |
RFmxCdma2kMXQevmSpectrumInverted | Specifies whether the spectrum of the signal is inverted. |
RFmxCdma2kMXRadioConfiguration | Specifies the radio configuration for the channel. |
RFmxCdma2kMXSemAveragingEnabled | Specifies whether to enable averaging for the SEM measurement. |
RFmxCdma2kMXSemAveragingType | Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the SEM measurement. |
RFmxCdma2kMXSemLowerOffsetMeasurementStatus | Indicates the lower offset segment measurement status based on measurement limits specified by the standard.Use "offset(n)" as the Selector Strings to read this result. |
RFmxCdma2kMXSemMeasurementStatus | Indicates the overall measurement status based on the measurement limits, which are specified by the standard for each offset segment. |
RFmxCdma2kMXSemOffsetRbwFilterType | Returns the type of RBW filter used to sweep the offset segment. |
RFmxCdma2kMXSemSweepTimeAuto | Specifies whether the measurement computes the sweep time. |
RFmxCdma2kMXSemUpperOffsetMeasurementStatus | Indicates the upper offset measurement status based on measurement limits set by the standard.Use "offset(n)" as the Selector Strings to read this result. |
RFmxCdma2kMXSlotPhaseReceiveFilterEnabled | Specifies whether to enable the received filter for the SlotPhase measurement. Use this method to disable the filter, if the received signal is already filtered. Specifies whether to enable the received filter for the SlotPhase measurement. Use this method to disable the filter, if the received signal is already filtered. |
RFmxCdma2kMXSlotPhaseSpectrumInverted | Specifies whether the spectrum of the signal is inverted. |
RFmxCdma2kMXSlotPhaseSynchronizationMode | Specifies whether the measurement is performed from the frame or slot boundary. |
RFmxCdma2kMXSlotPowerReceiveFilterEnabled | Specifies whether to enable the received filter for the SlotPower measurement. Use this method to disable the filter, if the received signal is already filtered. |
RFmxCdma2kMXSlotPowerSpectrumInverted | Specifies whether the spectrum of the signal is inverted. |
RFmxCdma2kMXSlotPowerSynchronizationMode | Specifies whether the measurement is performed from the frame or slot boundary. |
RFmxCdma2kMXTriggerMinimumQuietTimeMode | Specifies whether the measurement computes the minimum quiet time used for triggering. |
RFmxCdma2kMXTriggerType | Specifies the trigger type. |
Delegates
None