Methods
| Name | Description |
|---|---|
| ConfigureAveraging(string, RFmxCdma2kMXQevmAveragingEnabled, int) | Configures averaging for QEVM measurement. |
| ConfigureMeasurementLength(string, int) | Configures the number of chips used for a single QEVM measurement iteration. |
| GetAllTracesEnabled(string, out bool) | Gets whether to enable the traces to be stored and retrieved after performing the QEVM measurement. |
| GetAveragingCount(string, out int) | Gets the number of measurements used for averaging when you set the SetAveragingEnabled(string, RFmxCdma2kMXQevmAveragingEnabled) method to True. |
| GetAveragingEnabled(string, out RFmxCdma2kMXQevmAveragingEnabled) | Gets whether to enable averaging for the QEVM measurement. |
| GetIQGainImbalanceRemovalEnabled(string, out RFmxCdma2kMXQevmIQGainImbalanceRemovalEnabled) | Gets whether to remove I/Q gain imbalance before QEVM measurement. |
| GetIQOffsetRemovalEnabled(string, out RFmxCdma2kMXQevmIQOffsetRemovalEnabled) | Gets whether to remove I/Q offset before QEVM measurement. |
| GetIQQuadratureErrorRemovalEnabled(string, out RFmxCdma2kMXQevmIQQuadratureErrorRemovalEnabled) | Gets whether to remove I/Q quadrature error before QEVM measurement. |
| GetMeasurementEnabled(string, out bool) | Gets whether to enable the QEVM measurement. |
| GetMeasurementLength(string, out int) | Gets the number of chips used for a single measurement. |
| GetNumberOfAnalysisThreads(string, out int) | Gets the maximum number of threads used for parallelism for the QEVM measurement. |
| GetReceiveFilterEnabled(string, out RFmxCdma2kMXQevmReceiveFilterEnabled) | Gets whether to enable the received filter for the QEVM measurement. |
| GetSpectrumInverted(string, out RFmxCdma2kMXQevmSpectrumInverted) | Gets whether the spectrum of the signal is inverted. |
| SetAllTracesEnabled(string, bool) | Sets whether to enable the traces to be stored and retrieved after performing the QEVM measurement. |
| SetAveragingCount(string, int) | Sets the number of measurements used for averaging when you set the SetAveragingEnabled(string, RFmxCdma2kMXQevmAveragingEnabled) method to True. |
| SetAveragingEnabled(string, RFmxCdma2kMXQevmAveragingEnabled) | Sets whether to enable averaging for the QEVM measurement. |
| SetIQGainImbalanceRemovalEnabled(string, RFmxCdma2kMXQevmIQGainImbalanceRemovalEnabled) | Sets whether to remove I/Q gain imbalance before QEVM measurement. |
| SetIQOffsetRemovalEnabled(string, RFmxCdma2kMXQevmIQOffsetRemovalEnabled) | Sets whether to remove I/Q offset before QEVM measurement. |
| SetIQQuadratureErrorRemovalEnabled(string, RFmxCdma2kMXQevmIQQuadratureErrorRemovalEnabled) | Sets whether to remove I/Q quadrature error before QEVM measurement. |
| SetMeasurementEnabled(string, bool) | Sets whether to enable the QEVM measurement. |
| SetMeasurementLength(string, int) | Sets the number of chips used for a single measurement. |
| SetNumberOfAnalysisThreads(string, int) | Sets the maximum number of threads used for parallelism for the QEVM measurement. |
| SetReceiveFilterEnabled(string, RFmxCdma2kMXQevmReceiveFilterEnabled) | Sets whether to enable the received filter for the QEVM measurement. |