PXIe-2790 Overview

PXIe-2790 Pinout


1378

Table 1. Signal Descriptions
Signal Description
CHxA Bank A signal connection
CHxB Bank B signal connection
COMx Routing destination for channels on the corresponding bank
SUMAB Combined output connection

PXIe-2790 Topology

This figure describes the topology of the module.

Module software name: 2790/Independent (NISWITCH_TOPOLOGY_2790_INDEPENDENT)

Independent Topology


1378

Making a Connection

Call the niSwitch Connect Channels VI or the niSwitch_Connect function to connect channels in this topology. If applicable, you must call the niSwitch Disconnect Channels VI or the niSwitch_Disconnect function to disconnect an existing connection before you call the niSwitch Connect Channels VI or the niSwitch_Connect function.

The initially connected channels on the module are sumAB to comA and sumAB to comB. Banks A and B operate independently.

  • To connect ch1A to comA, disconnect sumAB from comA and connect ch1A to comA.
  • To connect ch1B to comB, disconnect sumAB from comB and connect ch1B to comB.