niHSDIO HWC Fetch Sample Errors (U32) VI
- Updated2023-02-21
- 4 minute(s) read
Returns the sample error information from a hardware comparison operation.
Related Topics
![]() |
instrument handle identifies your instrument session. instrument handle is obtained from the niHSDIO Init Acquisition Session VI, the niHSDIO Init Generation Session VI, or the niHSDIO Init Ext Cal VI. |
||||||
![]() |
sample errors to read specifies the number of sample errors to read. |
||||||
![]() |
max time milliseconds specifies, in milliseconds, the time allotted for the VI to complete before NI-HSDIO returns a timeout error. If you set the value to -1, the VI never times out. If you set this parameter to 0, the VI returns immediately with up to the number of samples specified in samples to read. If samples to read is greater than the number of samples in the device memory and all the available samples are acquired before a timeout, NI-HSDIO returns the available samples. |
||||||
![]() |
error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.
|
||||||
![]() |
instrument handle out passes a reference to your instrument session to the next VI. instrument handle is obtained from the niHSDIO Init Acquisition Session VI or the niHSDIO Init Generation Session VI. |
||||||
![]() |
number of sample errors read returns the total number of sample errors read from device memory. |
||||||
![]() |
sample numbers returns the array of sample indexes in which an error occurred. |
||||||
![]() |
error bits returns an array containing the channels, or bits, in which an error occured for each sample with an error. 1 indicates an error. 0 indicates no error. |
||||||
![]() |
repeat count returns the number of times the error was repeated. This parameter only yields data when the Filter Repeated Sample Errors property is set to True. |
||||||
![]() |
error out contains error information. This output provides standard error out functionality.
|