Installing MXI Cables
- Updated2023-04-11
- 2 minute(s) read
Installing MXI Cables
Note You must use an
RTM-3661 module with the ATCA-3671 module for host access to the FPGAs from LabVIEW. Direct host access is not supported for other RTMs.
-
Connect one end of a Gen3 MXI cable to the corresponding port on the installed RTM-3661 module for each FPGA.
- Start with Port 1 when you connect the MXI card. Connect MXI Port 1 to the first PCIe port (0, 1, ...) on the RTM that corresponds to the first FPGA (A, B, C, or D) to which you will connect.
-
Continue making connections in ascending order until you have made all necessary connections.
For example, if you require two connections to FPGA B and one connection to FPGA C, first connect Port 1 on the MXI Card to PCIe B, Port 0 on the RTM. Then connect Port 2 on the MXI Card to PCIe B, Port 1 on the RTM. Finally, connect Port 3 on the MXI Card to PCIe C, Port 0 on the RTM.
-
Connect the other end of the Gen3 MXI cable to a compatible Gen3 MXI PCI Express or PXI Express adapter on the host computer or PXI chassis.
Refer to the Gen3 MXI documentation for any additional connectivity requirements.
- Power on the ATCA-3671 after all desired MXI connections are made between the RTM-3661 and host-side adapters.
-
Wait 90 seconds and then power on the host computer or PXI controller.
Some host-side MXI adapters, such as the PXIe-8394 module, have a link status LED to indicate that a PCI Express link has been established successfully between the target and host. Refer to the Gen3 MXI x8 documentation to verify whether a link status LED may be used to verify the presence of a host link as the computer starts.