The following items are notable issues fixed between the release of VeriStand 2020 R6 and VeriStand 2021, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of VeriStand.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1181886 |
System Definition File created with (ECUMC) System Definition API uses invalid "SupportedTarget" entryUsing the System Definition API to create a system definition file which includes an ECUMC Custom Device fails to deploy on Windows.
Workaround: Edit the system definition file to use "PharLap & Windows" in the "Driver VI Path_X" node. The source distribution is found and deployment is successful.
|
Reported Version: VeriStand 2020 R4 Resolved Version: VeriStand 2021 Added: Apr 16, 2021 |
|
116076 | 650143 |
Model parameter files do not import correctly when Windows localization settings specify "," as the decimal separatorParameters included
in the Stimulus Profile Editor shipping example fail to import because model parameter
files generally do not support commas as a delimiter.
Workaround: Change the Windows system language to English before importing model parameter files.
|
Reported Version: VeriStand 2016 Resolved Version: VeriStand 2021 Added: Jul 26, 2021 |
1505083 |
Error 363504 returned when restarting the VeriStand engine on a password-protected RT TargetThe Restart VeriStand
Engine button found in the Document pane of the Mapping Diagram generates an
error when the connected RT target is
password-protected. Workaround: Set a blank password for the RT controller.
|
Reported Version: VeriStand 2019 R3 Resolved Version: VeriStand 2021 Added: Jul 26, 2021 |
|
375107 | 352124 |
Stimulus Profile Editor displays error when viewed on a remote machineThe Stimulus Profile Editor returns a 'This freezable cannot be frozen' error when interacting with SandDoc components. This error occurs when connecting to a remote Windows system with the 'Windows Classic' theme enabled. Workaround: There is currently no known workaround for this issue.
|
Reported Version: VeriStand 2011 SP1 Resolved Version: VeriStand 2021 Added: N/A |
1521278 |
Alarm Monitor does not work for alarms in foldersThe VeriStand Alarm Monitor does not function correctly on alarms that are inside folders in the Project Files pane. The following actions do not occur when alarms are in folders.
Workaround: Don't put the alarms in folders. Or write a custom tool using the LabVIEW API.
|
Reported Version: VeriStand 2020 R5 Resolved Version: VeriStand 2021 Added: N/A |
|
1618401 |
VeriStand cannot add channels to a logging specificationIn a logging specification document with too many existing channels, the Add channel window will appear offscreen. Enlarging the window can help, but only until reaching the end of the monitor.
Workaround: User could hand edit document in text editor to add channels to the log spec
|
Reported Version: VeriStand 2020 R6 Resolved Version: VeriStand 2021 Added: N/A |
|
1622497 |
VeriStand crashes due to ChromiumFX proxy authentication errorVeriStand crashes on second launch due to an issue with proxy authentication in ChromiumFX. The error is usually caused by IT policies preventing authentication. An exception returns from NIWebBrowserChromiumFx.RequestHandler_GetAuthenticationCredentials.
Workaround: Work with IT department to address authentication failure.
|
Reported Version: VeriStand 2020 R6 Resolved Version: VeriStand 2021 Added: N/A |
|
1719554 |
Screen memory leakScreen memory usage may grow by gigabytes over a 15-30 minute time span. This can occur in a Screen with certain control types under a heavy workload. For example, Screens with hundreds of updating numeric indicators and a chart with hundreds of channels are more likely to experience a memory leak.
Workaround: Use a less complex screen that is processing less data.
|
Reported Version: VeriStand 2020 R5 Resolved Version: VeriStand 2021 Added: N/A |
|
1721945 |
VeriStand crashes while undeploying an active logging documentVeriStand may crash while undeploying a system definition with an active logging document. This crash typically occurs after the first or second undeploy attempt.
Workaround: Stop the logging before undeploying
|
Reported Version: VeriStand 2020 R5 Resolved Version: VeriStand 2021 Added: N/A |
|
1661320 |
VeriStand returns Error 1172 when loading a projectError 1172 is intermittently reported when opening a project with too many dependencies.
Workaround: There is currently no known workaround for this issue. |
Reported Version: VeriStand 2020 R4 Resolved Version: VeriStand 2021 Added: N/A |
Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.
These patches currently do not have any special instructions.