The following items are notable issues fixed between the release of LabVIEW 2019 Control Design and Simulation Module and LabVIEW 2020 Control Design and Simulation Module, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of LabVIEW 2020 Control Design and Simulation Module.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
225411 | 686393 |
Running two instances of any of the VIs related to Estimation VI palette will cause the instances to conflate signals.Running two instances of any of the VIs related to Estimation VI palette in Control & Simulation->Simulation will cause the instances to conflate signals. This is because the VIs are set to Shared Clone Reentrant Execution. Workaround: Manually set the necessary VIs in \LabVIEW 20xx\vi.lib\Simulation\Estimation\Implementation to Preallocated Clone Reentrant Execution. |
Reported Version: LV Control Design and Simulation: 2017 Resolved Version: LabVIEW 2020 Control Design and Simulation Module Added: May 20, 2018 |
These patches currently do not have any special instructions.