This document contains the MAX 19.0 and NI System Configuration 19.0 known issues that were discovered before and since the previous release. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.
This document contains the MAX 19.0 and System Configuration 19.0 known issues that were discovered before and since the release NI System Configuration 19.0. Not every issue known to NI will appear on this list; it is intended to only show the severe and common issues.
The following items are known issues in MAX 19.0 and NI System Configuration 19.0 sorted by Date.
ID | Known Issue | |||||
---|---|---|---|---|---|---|
587524 Return | NI-VISA Trigger Bus Query Property is not supported by NI System Configuration API. NI-VISA allowed users to query for the PXI Trigger Bus number using the instrument session handle but there is no similar functionality in the NI System Configuration API. Workaround: N/A
| |||||
633751 Return | NI MAX System Settings page doesn't populate when all host network adapters are disabled. On any system that either has no network adapters, or has all network adapters disabled, the Systems Settings page in NI MAX for My System does not populate. Workaround: Enable a network adapter on the machine.
| |||||
683930 Return | The Install Startup VI will reinstall all dependencies of the Real-Time startup executable even if those dependencies are present on the target When using the System Configuration API Install VI to install a startup executable to a Real-Time system, all dependencies of the executable will be reinstalled to the target. This installation will happen even if those dependencies were previously installed on the target. Workaround: N/A
| |||||
700712 Return | NI IO Trace on Linux displays only the hex code for properties instead of the property name When using NI IO Trace on a Linux Operating System, only the hex code will display for certain properties and not corresponding the property name. Workaround: Refer to nisyscfg.h for the numeric values that correspond to each property.
|