Vision Acquisition Software 18.0
ID | Fixed Issue |
---|---|
220427 | IMAQ Close and IMAQ Stop appear to hang when the acquisition is waiting for a trigger and the timeout has not yet elapsed. |
692292 | Existing 1473R bitfile cannot be used in LabVIEW 64-bit. |
678251 | Vision RIO output lines glitches when driving lines from different applications. |
675286 | Linux RT will crash if USB3 camera detected does not support events. |
692261 | GigE Acquisition returns error -52001 "Memory Cannot be Page Locked" in low-memory situations in LabVIEW 32 bit. |
667872 | CameraLink FPGA Centroid Example returns timeout error when only acquiring a single image. |
Vision Acquisition Software 18.5
ID | Fixed Issue |
---|---|
712396 | For Camera Link cameras using NI-IMAQdx, the TriggerDivider attribute doesn’t error when set to 0. |
711898 | For Camera Link cameras using NI-IMAQdx, the InvertLine attribute does not work on User Outputs. |
710873 | Non-streaming GigE Vision devices fail to open in NI-MAX. |
709909 | If a USB3 Vision camera has a flaky connection, the OS can renegotiate the connection and temporarily double enumerate the device before cleaning up the first instance, causing the driver to incorrectly not identify the original camera session as removed. |
707598 | After a camera is unplugged, the driver sometimes returns no acquisition in progress error instead of camera removed error. |
707491 | Unplugging a camera during an acquisition can cause a crash in LabVIEW or result in GetImage returning “Attribute not supported by the camera” instead of a more meaningful error. |
707402 | When a USB3 Vision camera is removed, subsequent calls to GetImage return timeout instead of more meaningful error indicating the camera has been unplugged. |
707186 | If the USB stream of a USB3 Vision camera experiences a communication failure during an acquisition, GetImage() returns timeout instead of more meaningful error. |
705795 | If an NXG VI has multiple resources controls, each control may not correctly refresh the list of currently available devices. |
704305 | Blue Screen can occur on Windows when performing serial read and write operations on Camera Link. |
507186 | A One Shot acquisition cannot be started again after it has completed without first unconfiguring and configuring the acquisition. |
173143 | One Shot acquisitions do not correctly indicate that the acquisition is complete after all of the buffers have been acquired. |
716920 | The 1433, 1435, and 1437 can experience unreliable serial communication about 115200 baud. |
717882 | Linux Real-Time target with a USB3 camera connected can become unreachable through NI-MAX after NI-IMAQdx 18.5 software install. |
719679 | When upgrading to Vision Acquisition Software 18.5, the Vision Acquisition Express VI might not be available in certain versions of LabVIEW. |