ID | Known Issue | Affected Driver Versions |
---|---|---|
691957 | Scales tab is unavailable in Measurement and Automation Explorer (MAX) for Industrial Controller targets. | NI Industrial Controller 17.5 and newer |
623854 | When DAQmx and IMAQdx are both installed on a Linux x64 target, reinstalling IMAQdx causes the target to become unreachable in MAX | NI Industrial Controller 15.5 and newer |
Known Issues with NI Industrial Controller Device Drivers 18.0
ID | Known Issues |
---|---|
691957 |
Scales tab is unavailable in Measurement and Automation Explorer (MAX) for Industrial Controller targets Workaround: Configure and use Scales programmatically |
623854 |
When DAQmx and IMAQdx are both installed on a Linux x64 target, reinstalling IMAQdx causes the target to become unreachable in MAX Workaround: Restarting the target in safe mode allows it to be accessed and reformatted, which will fix the issue. More details on this issue and workaround can be found by navigating to http://www.ni.com/info and searching for info code LVRTfail
|