This document contains the NI VeriStand 2017 known issues that were discovered before and since the release of NI VeriStand 2017. Not every issue known to NI will appear on this list; it is intended to only show the severe and more common issues that can be encountered.
The following items are known issues in NI VeriStand 2017 sorted by Date.
ID | Known Issue | |||||
---|---|---|---|---|---|---|
317883 Return | Using % in a block name causes a The MathWorks Inc. Simulink® model to fail to build Using % in a block name causes a The MathWorks Inc. Simulink® model to fail to build Workaround: Do not use % in the block name.
| |||||
383092 Return | Streaming a large number of waveform graphs can cause VeriStand gateway to stop responding Streaming a large number of waveforms to the waveform graph can cause the VeriStand gateway to be overwhelmed and stop responding in a timely fashion. Workaround: Reduce CPU usage on the gateway computer or stream fewer waveforms.
| |||||
386381 Return | The Pulse Measurement task may return incorrect data In certain configurations where the signal is disconnected or has a 0/100% duty cycle, the Pulse Measurement task may report invalid readings. The returned reading of the disconnected signal will be the last non 0/100% duty cycle processed by your device. Workaround: Install NI DAQmx 9.7 drivers
| |||||
392092 Return | Error -200452 occurs when a 433x device uses hardware timed single point If a 433x device is set as the master or if there is only a 433x device in a system definition, using hardware timed single point will cause error -200452 to occur during deployment. Workaround: Use at least one other device in the system definition
| |||||
402293 Return | Model files imported to VeriStand with vector channels appear as Nx1 rather than 1xN Model files imported to VeriStand with vector channels appear as Nx1 rather than 1xN making it impossible to map to the channel correctly. Workaround: Use the channel mappings dialog to import from a text file instead of using the dialog.
| |||||
522678 Return | Adding an FPGA target to the System Definition via the API will fail to add the Parameters section of PWM channels When using the System Definition API to programmatically add an FPGA target to a System Definition file, the Parameters section typically included with PWM channels is excluded. Workaround: Add the FPGA manually to the System Definition via the System Explorer.
| |||||
527148 Return | Programmatic deployment of VeriStand Projects to password protected targets requires user interaction When deploying a VeriStand Project to a real-time target protected with a password a user is required to interact with a login dialog box. Consequently, programmatic deployment using the API still requires user interaction, preventing truly headless deployment. Workaround: Have an operator interact with the dialog box or do not use password protected targets for programmatic deployments.
| |||||
372874 Return | Building a LabVIEW model for NI VeriStand fails if the controls or indicators have identical names. When building a VI into a model for NI VeriStand, the build process will fail if any of the indicators or controls have identical names. Workaround: Use different names for the controls and indicators that will become the model's inports and outports.
| |||||
572887 Return | Setting the Frame Type option in the Raw Data Frame Configuration page has no effect. As the Frame Type is pulled from the XNET database, this System Definition setting does not affect the XNET configuration. Workaround: Set the Frame Type as desired in the XNET database. Do not use the Raw Data Frame Type Configuration option in the System Definition.
| |||||
581727 Return | XNET Database deployment fails on password-protected target When deploying a VeriStand system definition which contains an XNET database to a password-protected real-time target, the deployment fails, displaying the message, "File transfer communication with the LabVIEW Real-Time (RT) target failed." Workaround: Deploy XNET database manually before using VeriStand to deploy the rest of the system.
| |||||
590854 Return | Not possible to disable the VeriStand workspace When UI Manager is used in a VeriStand project, both UI Manager and the Workspace are launched at execution time. There is currently no way to disable this. Workaround: Launch your VeriStand project silently and then manually open UI Manager.
| |||||
468712 Return | VeriStand may select a DAQ card with Slow Background Conversion mode enabled as the chassis master timing device If Slow Background Conversion mode is enabled on a DAQ card (like a PXIe-4353) and it's the first DAQ device listed in the system definition, VeriStand incorrectly tries to use this device as the master timing card. VeriStand will do this even if there are other DAQ cards running without Slow Background Conversion enabled. Workaround: Add the DAQ card that you want to use as the master timing source to the system definition before adding the Slow Background Conversion DAQ card. If both cads are already in the system definition, remove and re-add the Slow Background Conversion-enabled card.
| |||||
654632 Return | Models built in LabVIEW 2017 fail to deploy to RT PXI and cRIO-908x targets running NI VeriStand 2017 Deployment of a VeriStand project to RT PXI or cRIO-908x targets running NI VeriStand 2017 will fail when one or more models built in LabVIEW are included in the System Definition. Workaround: Install the VeriStand 2017 f1 patch.
| |||||
676011 Return | Some Indicators May Behave as Controls in UI Manager 2017 In UI Manager 2017, it may be possible to update underlying channel values by editing the value of some types of indicators used on the screen as if they were controls. Workaround: Do not modify these indicator values unless an update to the underlying channel value is desired.
| |||||
678060 Return | VeriStand UI Manager 2017 can crash if the time zone on the host is set to UTC + 6:30 or later. VeriStand UI Manager 2017 can crash if the time zone on the host machine is set to UTC + 6:30 or later when manually associating a UI Manager project with a VeriStand System Definition. Workaround: Install the VeriStand UI Manager 2017 f1 patch or change the time zone on the host to UTC + 6:00 or earlier.
|
The following items are known issues in NI VeriStand 2017 sorted by Category.
ID | Known Issue | |||||
---|---|---|---|---|---|---|
Miscellaneous | ||||||
386381 Return | The Pulse Measurement task may return incorrect data In certain configurations where the signal is disconnected or has a 0/100% duty cycle, the Pulse Measurement task may report invalid readings. The returned reading of the disconnected signal will be the last non 0/100% duty cycle processed by your device. Workaround: Install NI DAQmx 9.7 drivers
| |||||
392092 Return | Error -200452 occurs when a 433x device uses hardware timed single point If a 433x device is set as the master or if there is only a 433x device in a system definition, using hardware timed single point will cause error -200452 to occur during deployment. Workaround: Use at least one other device in the system definition
| |||||
676011 Return | Some Indicators May Behave as Controls in UI Manager 2017 In UI Manager 2017, it may be possible to update underlying channel values by editing the value of some types of indicators used on the screen as if they were controls. Workaround: Do not modify these indicator values unless an update to the underlying channel value is desired.
| |||||
678060 Return | VeriStand UI Manager 2017 can crash if the time zone on the host is set to UTC + 6:30 or later. VeriStand UI Manager 2017 can crash if the time zone on the host machine is set to UTC + 6:30 or later when manually associating a UI Manager project with a VeriStand System Definition. Workaround: Install the VeriStand UI Manager 2017 f1 patch or change the time zone on the host to UTC + 6:00 or earlier.
| |||||
Model Interfacing | ||||||
317883 Return | Using % in a block name causes a The MathWorks Inc. Simulink® model to fail to build Using % in a block name causes a The MathWorks Inc. Simulink® model to fail to build Workaround: Do not use % in the block name.
| |||||
402293 Return | Model files imported to VeriStand with vector channels appear as Nx1 rather than 1xN Model files imported to VeriStand with vector channels appear as Nx1 rather than 1xN making it impossible to map to the channel correctly. Workaround: Use the channel mappings dialog to import from a text file instead of using the dialog.
| |||||
372874 Return | Building a LabVIEW model for NI VeriStand fails if the controls or indicators have identical names. When building a VI into a model for NI VeriStand, the build process will fail if any of the indicators or controls have identical names. Workaround: Use different names for the controls and indicators that will become the model's inports and outports.
| |||||
654632 Return | Models built in LabVIEW 2017 fail to deploy to RT PXI and cRIO-908x targets running NI VeriStand 2017. Deployment of a VeriStand project to RT PXI or cRIO-908x targets running NI VeriStand 2017 will fail when one or more models built in LabVIEW are included in the System Definition. Workaround: Install the VeriStand 2017 f1 patch.
| |||||
Performance | ||||||
383092 Return | Streaming a large number of waveform graphs can cause VeriStand gateway to stop responding Streaming a large number of waveforms to the waveform graph can cause the VeriStand gateway to be overwhelmed and stop responding in a timely fashion. Workaround: Reduce CPU usage on the gateway computer or stream fewer waveforms.
| |||||
590854 Return | Not possible to disable the VeriStand workspace When UI Manager is used in a VeriStand project, both UI Manager and the Workspace are launched at execution time. There is currently no way to disable this. Workaround: Launch your VeriStand project silently and then manually open UI Manager.
| |||||
System Explorer | ||||||
572887 Return | Setting the Frame Type option in the Raw Data Frame Configuration page has no effect. As the Frame Type is pulled from the XNET database, this System Definition setting does not affect the XNET configuration. Workaround: Set the Frame Type as desired in the XNET database. Do not use the Raw Data Frame Type Configuration option in the System Definition.
| |||||
581727 Return | XNET Database deployment fails on password-protected target When deploying a VeriStand system definition which contains an XNET database to a password-protected real-time target, the deployment fails, displaying the message, "File transfer communication with the LabVIEW Real-Time (RT) target failed." Workaround: Deploy XNET database manually before using VeriStand to deploy the rest of the system.
| |||||
468712 Return | VeriStand may select a DAQ card with Slow Background Conversion mode enabled as the chassis master timing device If Slow Background Conversion mode is enabled on a DAQ card (like a PXIe-4353) and it's the first DAQ device listed in the system definition, VeriStand incorrectly tries to use this device as the master timing card. VeriStand will do this even if there are other DAQ cards running without Slow Background Conversion enabled. Workaround: Add the DAQ card that you want to use as the master timing source to the system definition before adding the Slow Background Conversion DAQ card. If both cads are already in the system definition, remove and re-add the Slow Background Conversion-enabled card.
| |||||
Using the API | ||||||
522678 Return | Adding an FPGA target to the System Definition via the API will fail to add the Parameters section of PWM channels When using the System Definition API to programmatically add an FPGA target to a System Definition file, the Parameters section typically included with PWM channels is excluded. Workaround: Add the FPGA manually to the System Definition via the System Explorer.
| |||||
527148 Return | Programmatic deployment of VeriStand Projects to password protected targets requires user interaction When deploying a VeriStand Project to a real-time target protected with a password a user is required to interact with a login dialog box. Consequently, programmatic deployment using the API still requires user interaction, preventing truly headless deployment. Workaround: Have an operator interact with the dialog box or do not use password protected targets for programmatic deployments.
|