Known Issues

The following items are known issues in NI-OSI.

NI-OSI 1.0

IDKnown Issue
243134Threshold settings in spectral view will not be set without Sen0 in the Channel. If you try to configure peak search parameters (threshold, width, etc) in the spectral view of OSI Explorer and there is not a Sen0 in the channel, then the newly made configuration will not be saved.

 

NI-OSI 2.0

IDKnown Issue
364061Switching Between RT and My Computer While in Spectrum View Does Not Update Cursors Correctly
364327OSI API Does Not Always Fully Clear Session When 4844 is Reset
360513Sensor Tag Inputs With Certain Syntax Errors Work Correctly But Do Not Generate An Error Message

 

NI-OSI 2.1

IDKnown Issue
364061Switching Between RT and My Computer While in Spectrum View Does Not Update Cursors Correctly
364327OSI API Does Not Always Fully Clear Session When 4844 is Reset
360513Sensor Tag Inputs With Certain Syntax Errors Work Correctly But Do Not Generate An Error Message
422766OSI Channel and OSI Sensor Controls Do Not Auto Populate for LabVIEW 2010 and 2011
411367Pharlap Target May Crash When Attempting to Set Permissions from MAX

 

NI-OSI 16.0

IDKnown Issue
364061Switching Between RT and My Computer While in Spectrum View Does Not Update Cursors Correctly
364327OSI API Does Not Always Fully Clear Session When 4844 is Reset
360513Sensor Tag Inputs With Certain Syntax Errors Work Correctly But Do Not Generate An Error Message
422766OSI Channel and OSI Sensor Controls Do Not Auto Populate for LabVIEW 2010 and 2011
411367Pharlap Target May Crash When Attempting to Set Permissions from MAX
640259NI-OSI 16.0 will not install over NI-OSI 2.1. Required to uninstall NI-OSI 2.1 in order to update driver

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).