The following items are Bug Fixes in LabVIEW SoftMotion Module 2014 f1.
ID | Fixed Issue | Issue Details |
---|---|---|
Scaling velocity with NI ISM or SMD devices results in unexpected behavior. | The units for commanded velocity incorrectly specified rev/second. This has been corrected to be configured as steps/second. | |
485347 | The Calculate Anti-Res Coefficients example VI has a broken run arrow. | An example VI that shipped with LabVIEW 2014 SoftMotion Module was not functional. The example now functions as expected. |
485535 | Using unbound axes causes LabVIEW to hang. | Using an unbound axis would cause LabVIEW to hang when SoftMotion tried to locate a required resource. The instability has been resolved and unbound axes should function as expected. |
420789 | Deployment error when deploying Create Motion Reference VI to an RT target. | LabVIEW would present a deployment error when deploying all instances of a polymorphic VI without a valid SoftMotion license, even if the particular instance did not require a license. License enforcement has been corrected to apply only to instances which require a license. |