| ID | Known Issue |
|---|
246803
| Auto detection of resource blocks does not work when you set the number of PUSCH resource blocks to 1.
The toolkit cannot auto detect single resource blocks for all bandwdths.
Workaround: Set the Auto RB Detection Enabled property to False if you set the number of resource blocks to 1.
| Reported Version: 2.0 | | Resolved Version: N/A | | Added: 02/08/2012 |
|
276101
| Incorrect I/Q gain imbalance and quadrature skew measurements returned for asymmetric frequency domain allocations
The I/Q gain imbalance and quadrature skew impairments are estimated in the frequency domain. The algorithm assumes that the RB allocation is symmetric about the DC sub-carrier. If the RB allocation is not symmetric, the algorithm returns incorrect values.
Workaround: None
| Reported Version: 1.0 | | Resolved Version: N/A | | Added: 02/10/2011 |
|
317040
| SRS EVM measurement does not work for special subframes
The NI LTE 2.0 Toolkit does not support EVM measurements in the UpPTS field of the special subframe.
Workaround: Do not analyze special subframes.
| Reported Version: 2.0 | | Resolved Version: N/A | | Added: 02/08/2012 |
|
325982
| The PUCCH EVM deteriorates for some cell IDs
The PUCCH EVM deteriorates for cell IDs 175 and 375.
Workaround: None
| Reported Version: 2.0 | | Resolved Version: N/A | | Added: 02/08/2012 |
|
327603
| OBW measurement displays inconsistent results for PUCCH and sparsely-filled PUSCH
The OBW measurement displays inconsistent results for fully-filled PUCCH and Low RB PUSCH.
Workaround: OBW measurement is not supported for PUCCH and sparsely-filled PUSCH.
| Reported Version: 2.0 | | Resolved Version: N/A | | Added: 02/08/2012 |
|
329207
| The toolkit does not apply trigger delay for ACP and SEM measurements
The toolkit does not apply trigger delay for 15 MHz and 20 MHz ACP and SEM measurements.
Workaround: None
| Reported Version: 2.0 | | Resolved Version: N/A | | Added: 02/08/2012 |
|
329842
| ModAcc measurements return incorrect results for uplink PUSCH and PUCCH occupied in certain subframes when the Measurement Mode is set to Specific Slot
ModAcc measurements return incorrect results for uplink PUSCH and PUCCH when the Measurement Mode is set to Specific Slot.
Workaround: None
| Reported Version: 2.0 | | Resolved Version: N/A | | Added: 02/08/2012 |
|
333815
| The toolkit displays an error when you increase the value of n_DMRS and enable auto detection for PUSCH TDD
The toolkit displays the "Unable to Synchronize" error message when you increase the value of n_DMRS and enable auto detection for PUSCH TDD.
Workaround: None
| Reported Version: 2.0 | | Resolved Version: N/A | | Added: 02/08/2012 |
|