NI does not actively maintain this document.
This content provides support for older products and technology, so you may notice outdated links or obsolete information about operating systems or other relevant products.
Each issue appears as a row in the table and includes the following fields:
ID | Known Issue | |||||
---|---|---|---|---|---|---|
365093 |
While using the SFP or CVI, BER results may be incorrect if you do not restrict the number of unique packets
| |||||
309253 | Gaussian RBW filter type does not give expected results for DF2 measurements. If you set the RBW filter type to Gaussian, the DF2 measurement values are low. Workaround: None
| |||||
300396 | DEVM measurements in loop back gradually degrade and fail as the payload length on generator is reduced from maximum to 1 (for all supported packet types) DEVM measurements in loop back give an expected result only when generated for the maximum packet payload length. The measurements gradually degrade and fail as the packet length is decreased. Workaround: None
| |||||
299800 | EV3 packet type is not supported for any modulation type The toolkit does not support the EV3 packet type for any modulation type. Workaround: None
| |||||
368856 | DF1 and DF2 measurements for FEC-encoded packets are incorrect when the packet length offset field is not zero DF1 and DF2 measurements for DM1, DM3, and DM5 packets are incorrect when the packet length offset field is not zero. Workaround: None
| |||||
369733 | The toolkit cannot measure LE CFO and LE transmit power if you set the payload length less than the maximum payload length on the generator The toolkit cannot measure LE CFO and LE transmit power if you set the payload length less than the maximum payload length on the generator. Workaround: None
|
Contact NI regarding this document or issues in the document. If you contact NI in regards to a specific issue, reference the ID number given in the document. The ID number contains the current issue ID number as well as the legacy ID number (use the current ID number when contacting NI). You can contact us through any of the normal support channels including phone, email, or the discussion forums. Visit the NI Website to contact us. Also contact us if you find a workaround for an issue that is not listed in the document.