Each issue appears as a row in the table and includes the following fields:
ID | Known Issue | |||||
---|---|---|---|---|---|---|
325036 | Reference Clock cannot be exported on the Ref Out terminal on the NI PXIe-5663E The following error generates when the NI PXIe-5663E is configured to export the Reference clock to the REF OUT terminal: The LO returned the following error: Requested value is not a supported value for this property. Property: NIRFSG_ATTR_EXPORTED_REF_CLOCK_OUTPUT_TERMINAL You Have Requested: RefOut, RefOut2 You Can Select: RefOut, RefOut2 Status Code: -223587 Workaround: Export the Reference clock to another terminal or downgrade your version of NI-RFSA to NI-RFSA 2.4.2.
| |||||
314690 | Error returns when calibrating an NI PXI-5650/5651/5652 When performing an external calibration at high power levels, calling the niRFSG 5652 Adjust ALC Calibration VI can return the following error: Please check the amplitude accuracy of your measurement instrument. Polynomial curve fit rejected LSB off by: x Even when calibration is accurate, the VI can return this error during external calibration of a NI PXI-5650/5651/5652. Workaround: N/A
| |||||
240669 | Dynamic wires do not work with peer-to-peer VIs in NI LabVIEW FPGA 2010 Using dynamic FPGA interfaces (also known as dynamic mode) in the LabVIEW FPGA Module is not supported when using peer-to-peer streaming. Dynamic mode is enabled by default in the LabVIEW FPGA Module 2010. Workaround: To disable Dynamic mode, complete the following steps:
| |||||
242645 | Incorrect error reporting behavior LabVIEW FPGA 2010 corrupts error reporting for NI-RFSG, and you may receive the following error message: Error information resources required by the driver could not be found on your system. Reinstall the driver or contact National Instruments Technical support. Workaround: Visit ni.com/kb and search for 5C1CGPJD for more information about how to correct error reporting behavior.
| |||||
258290 | A protocol violation error occurs when using an NI PXIe-1075 chassis When routing triggers across segments on the NI PXIe-1075 chassis, a protocol violation error may return. The NI PXIe-1075 has three bus segments: slots 1 through 6, slots 7 through 12, and slots 13 through 18. If the devices are located in different segments, you may run into this issue. Some features, such as RF list mode or NI-TClk when used for synchronization or MIMO applications, internally route triggers. Workaround: Visit ni.com/kb and search for 5FTGSP0O for more information about working around this issue.
| |||||
214278 | VIInt64 attributes not working on LabWindows/CVI VIInt64 attributes do not work on LabWindows/CVI 8.0 or earlier if versions of LabWindows/CVI 8.1 or later are installed prior to installing NI-RFSG. Workaround: Navigate to C:\Program Files\National Instruments\CVI80\include and replace visatype.h with visatype.h from C:\Program Files\National Instruments\CVI81\include or C:\Program Files\National Instruments\Shared\CVI\Include.
| |||||
215385 | Error when running NI-RFSG examples in LabWindows/CVI If you run NI-RFSG examples in LabWindows/CVI 8.0.x or 8.1.x and you have newer versions of LabWindows/CVI installed, you receive an error message that the niModInstCustCtrl.fp cannot be found. Workaround: Visit ni.com/kb and search for 4U1BQJ5F for more information about how to locate the missing files.
| |||||
248901 |
File corruption if installing on a system with NI-DAQmx 7.0 or 7.1
| |||||
192893 | Table of contents not locating When linking to a topic in the NI RF Signal Generators Help from the LabVIEW context help or opening the help file from a VI within LabVIEW, the NI RF Signal Generators Help launches and the relevant topic displays, but the location of the topic might not be highlighted in the table of contents. Workaround: N/A
| |||||
238196 | Warning about active content Microsoft Windows security feature that asks users whether or not to allow active content on their computer when launching certain pages from the driver media. Workaround: Select Yes when the active content warning appears.
| |||||
109764 | Measurement & Automation Explorer test panel does not work when running the NI PXIe-5673/5673E Running the test panel in Measurement & Automation Explorer (MAX) on the NI 5673/5673E when it is on an real-time system results in the following error: DAQmx Error -200170 occurred: Measurements: Physical channel specified does not exist on this device. Workaround: N/A
| |||||
150413 | Signal generates at the NI PXIe-5450 CLK OUT connector when Reference clock export is disabled First setting the Reference Clock Export Output property to Clkout or NIRFSG_ATTR_REF_CLOCK_EXPORT_OUTPUT attribute to NIRFSG_VAL_REF_OUT_STR and then changing the Reference Clock Export Output property to Do Not Export Signal or NIRFSG_ATTR_REF_CLOCK_EXPORT_OUTPUT attribute to NIRFSG_ATTR_DO_NOT_EXPORT_STR still causes a signal to generate on the CLK OUT front panel connector. Workaround: N/A
| |||||
248779 | NI PXIe-5650/5651/5652 takes 10 ms to hit target power level when switching to the divide by 16 path When switching to the divide by 16 path (any frequency between 100 MHz to 200 MHz) on the NI PXIe-5650/5651/5652, the output power behaves oddly. If you target 0 dBm on the device, the power starts off at approximately -25 dBm, but then overshoots to 10 dBm until it finally settles at approximately 0 dBm. Workaround: N/A
| |||||
314607 | A simulated NI PXI-5610 fails self-testing in Measurement & Automation Explorer Running self-test on a simulated NI PXI-5610 in the Measurement & Automation Explorer (MAX) causes the following error: Error -200437 occurred at Self-Test. Possible Reason(s): External calibration constants are invalid. Workaround: N/A
| |||||
316551 | Building LabVIEW with NI-RFSG fails When building an installer using LabVIEW with NI-RFSG included as part of the installation, the installer build fails and returns the following error: The system cannot find the path specified. When Microsoft Driver Framework (MDF) attempts to access NI-RFSG from the second volume of the stand-alone distribution, there is no setup.ini file located. MDF then searches the registry for the relative path between the root of the distribution and the Microsoft Installer Package (MSI). The problem is that the MDF does not verify that the source of the relative path is from the same distribution as the source of the root path (only that they are the same product version). It uses the first distribution it locates (alphanumerically) to get the relative path. Workaround: Visit ni.com/kb and search for 5QJ95VUS for more information about working around this issue.
| |||||
365962 |
In the device documentation, including the Getting Started Guide and Help file, the MAX "Configure" button is inaccurately labeled with its former name, "Properties." Workaround: When the documentation instructs you to select the "Properties" button, select the "Configure" button.
|
ID | Known Issue | |||||
---|---|---|---|---|---|---|
345543 |
Splash screen disappears before the NI-RFSG SFP finishes launching. When you launch the NI-RFSG SFP and select a device, there may be a five or more second delay after the splash screen disappears and before the SFP appears.
| |||||
346602 |
Switching from Ref In to Clk In when there is no signal on Clk In for the NI PXIe-5673 causes the device to enter an unknown state. If you configure the NI PXIe-5673E to use the Ref In as the reference clock source then change the reference clock source to Clk In, a message prompts you to connect a clock source to Clk In of Arb. When you cancel the message, the following error results: Error: The AWG reported the following error: PLL could not phase-lock to the external reference clock. Make sure your reference clock is connected and that it is within the jitter and voltage specifications. Changing a parameter value clears the error message, but the device remains in an error state.
| |||||
344365 |
Help»NI-RFSG SFP Help opens the Devices topic in the NI RF Signal Generators Help. When you select Help»NI-RFSG SFP Help, the help viewer opens to the Devices topic of the NI RF Signal Generators Help.
|
Contact NI regarding this document or issues in the document. If you contact NI in regards to a specific issue, reference the ID number given in the document. The ID number contains the current issue ID number as well as the legacy ID number (use the current ID number when contacting NI). You can contact us through any of the normal support channels including phone, email, or the discussion forums. Visit the NI Website to contact us. Also contact us if you find a workaround for an issue that is not listed in the document.