USB-6218

Part number(s):
780106-01
781005-01
779678-01
196203-01

Isolated 32 AI (16-Bit, 250 kS/s), 2 AO (250 kS/s), 8 DI, 8 DIO USB Multifunction I/O Device

Overview

The USB-6218 is an isolated, multifunction DAQ device. It offers analog I/O, digital input, digital output, and two 32-bit counters. For improved accuracy and safety, the USB-6218 provides 60 V, CAT I isolation. It also features signal streaming technology that gives you DMA-like bidirectional high-speed streaming of data across USB. The device is ideal for test, control, and design applications including portable data logging, field monitoring, embedded OEM, in-vehicle data acquisition, and academic. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

USB-6218 Details

Part Numbers (4) Price
780106-01
781005-01
779678-01
196203-01
NI Lead Time
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
Number of Bidirectional Digital Channels
0
0
0
0
Supported Power Input
Bus Powered
Bus Powered
Bus Powered
Bus Powered
Maximum Number of Single-Ended Analog Input Channels
32
32
32
32
Number of Counters/Timers
2
2
2
2
Maximum Number of Differential Analog Input Channels
16
16
16
16
Analog Input Absolute Accuracy
2690 μV
2690 μV
2690 μV
2690 μV
Analog Input FIFO Buffer Size
4095 samples
4095 samples
4095 samples
4095 samples
Maximum Sample Rate
250 kS/s
250 kS/s
250 kS/s
250 kS/s
Analog Input Isolation

60 V Ch-Earth Ground Isolation
60 V Ch-Earth Ground Isolation

Simultaneous Sampling
No
No
No
No
Enclosed
Yes
Yes
Yes
No
Analog Input Resolution
16 bits
16 bits
16 bits
16 bits
Bus Connector
USB 2.0
USB 2.0
USB 2.0
USB 2.0
Front Connection Type
Screw Terminal(1)
BNC(15)
Screw Terminal(1)
Generic (OEM)(1)
Number of Analog Output Channels
2
2
2
2
Maximum Analog Update Rate
250 kS/s
250 kS/s
250 kS/s
250 kS/s
Reconfigurable




Number of Analog Input Channels




Maximum Digital Update Rate




Operating Temperature Range




Bus Connection
USB 2.0
USB 2.0
USB 2.0
USB 2.0
Current Flow Direction




Digital I/O Isolation




Digital I/O Logic Levels




Maximum Clock Rate




Number of Digital Input Only Channels
8
8
8

Number of Digital Output Only Channels
8
8
8

Number of External Clock Inputs




Relay Type




Signaling Type




Supports Peer To Peer Streaming




Analog Input Voltage Range
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
Filtering




Number of Current Output Channels




Number of Voltage Output Channels




Analog Output Voltage Range




Output Current Range




Analog Output Isolation




Analog Output Resolution

16 bits
16 bits
16 bits
Analog Input Maximum Absolute Accuracy




Product Description
NI USB-6218 Isolated Bus-Powered M Series for Linux and Mac
USB-6218 BNC Bus-Powered M Series
USB-6218 Isolated Bus M Series w/Signal Express LE for Windows
USB-6218 OEM Isolated Board Only Kit (No Enclosure)

USB-6218 Accessories and Software

  • Product (Part Number)
    Description
    Recommended use cases
    FlexLogger Professional (785748-3501)
    FlexLogger Professional, Subscription License, Download

    Recommended for automated, extensible data logging with NI data acquisition (DAQ) hardware. Automate tests using alarms, triggers, and events, and expand capabilities with plug-ins.

    Key Features

    • Multichassis synchronization—Synchronize multiple NI chassis for accurate, time-aligned measurements across high channel counts.
    • Logging triggers—Start, stop, or segment data recording automatically based on sensor thresholds or other conditions to capture only what matters.
    • Events—Respond to specific occurrences during a test, such as activating equipment when a condition is met (for example, start cooling fans when temperature exceeds a limit).
    • Automation APIs—Control and monitor FlexLogger from external applications (Python, NI LabVIEW, or NI TestStand), enabling integration into larger automated test systems.
    • Calculation channels—Perform real-time math on acquired data (averages, RMS, custom formulas) to track derived measurements as the test runs.
    • Plug-ins—Extend FlexLogger with custom LabVIEW or Python plug-ins to integrate third-party hardware, perform custom analysis, or connect to lab systems.
    • CAN/LIN logging—Acquire and log automotive network data alongside sensor measurements for complete vehicle or subsystem testing.
    LabVIEW+ Suite (788509-35)
    NI LabVIEW+ Suite, Subscription License, Download

    Recommended for engineers building full test and validation systems where modular code development and higher-level frameworks are needed to accelerate development for shorter time to market.

    The LabVIEW+ Suite includes the following products:

    • NI LabVIEW—Provides a graphical programming environment for test system development, enabling connectivity to any instrument and fully integrated user interfaces.
    • NI TestStand—Eliminates the need for time-intensive in-house sequencer development and maintenance by providing an off-the-shelf test management software for validation and production test.
    • NI DIAdem—Saves engineers hundreds of hours of manual data analysis and report creation with automation.
    • NI FlexLogger™ software—Simplifies data acquisition and data logging with interactive measurement setup for NI DAQ hardware.
    • NI InstrumentStudio™ software—Provides a central location for configuration, measurement, and automation.

Support