FlexLogger New Features and Changes

Learn about updates, including new features and behavior changes, introduced in each version of FlexLogger.

Discover what is new in the latest releases of FlexLogger.
Note If you cannot find new features and changes for your version, it might not include user-facing updates. However, your version might include non-visible changes such as bug fixes and compatibility updates. For information about non-visible changes, refer to your product Release Notes.

FlexLogger 2025 Q4 Changes

Learn about new features, behavior changes, and other updates in FlexLogger 2025 Q4.

  • Added support for the following hardware:
    • PXIe-4311 analog input module
      Note Support added for voltage and current measurements only.
    • NI-9320 C-series voltage input module
  • Added logging optimizations that reduce log file sizes for files that contain digital channels.
  • Use the Elapsed Time logging trigger to start or change the logging rates for your tests after a certain amount of time passes.
  • Use the Button Pressed logging control to manually control your test logging rate, raising it to the maximum sample rate to analyze operator-detected behaviors and lowering the logging rate afterwards.
  • Use the Save As function in the LabVIEW and Python automation APIs for FlexLogger to programmatically save a copy of your FlexLogger project.
  • FlexLogger now supports synchronizing multiple TSN sync groups when using multi-chassis or network synchronization, instead of only synchronizing the largest sync group.
  • FlexLogger 2025 Q4 has the following support and compatibility updates:
    • LabVIEW automation support for FlexLogger 2025 Q4 requires LabVIEW 2025 Q3 or later.
    • TestStand automation support for FlexLoger 2025 Q4 requires TestStand 2025 Q2 or later.
    • Added support for Python 3.11, 3.12, and 3.13 to the FlexLogger Python Automation API.

FlexLogger 2025 Q3 Changes

Learn about new features, behavior changes, and other updates in FlexLogger 2025 Q3.

  • Added support for the following hardware:
    • PCIe-6340/6342/6350/6352 multifunction I/O devices
    • PXIe-6321/6323/6343/6351/6353/6357 multifunction I/O modules
  • Find detailed API reference documentation for the FlexLogger Plug-In Development Kit in-product or online at ni.com/docs. Refer to the FlexLogger Plug-In Development Kit API Reference for more information.

FlexLogger 2025 Q1 Changes

Learn about new features, behavior changes, and other updates in FlexLogger 2025 Q1.

  • Added support for the following devices:
    • cDAQ-9183/9187 Ethernet chassis
    • cDAQ-9173/9177 chassis
    • NI-9204
  • Added support for the following mioDAQ functionality:
    • Built-in CJC thermocouples
    • PFI trigger filter
  • Extend the functionality of FlexLogger with the FlexLogger step in TestStand.
  • Find and download plug-ins created by FlexLogger users on the FlexLogger Community Plug-ins Github repository.
  • Delete MAX configurations for simulated hardware from within FlexLogger without opening an additional program.

FlexLogger 2024 Q4 Changes

Learn about new features, behavior changes, and other updates in FlexLogger 2024 Q4.

  • Extend the functionality of FlexLogger with the FlexLogger LabVIEW API.
  • Use the FlexLogger Python API or the FlexLogger LabVIEW API to programmatically disable channel logging.
  • Connect your hardware to FlexLogger using the Hardware Configuration Utility instead of Measurement & Automation Explorer.
  • Improve loading times when opening large projects. Navigate to File » Preferences » Preview features and enable Save and load engine configuration files.

FlexLogger 2024 Q3.1 New Features and Changes

  • Added support for the following NI mioDAQ devices:
    • USB-6421
    • USB-6423
    • USB-6451
    • USB-6453

FlexLogger 2024 Q3 New Features and Changes

  • Support for LabVIEW 2024 in the FlexLogger Plug-in Development Kit 2024 Q3.
  • Use the Min-Max plug-in to calculate the minimum or maximum value for a group of channels. NI created the Min-Max plug-in using the FlexLogger Plug-in Development Kit. The Min-Max plug-in installs with FlexLogger.

    Add the plug-in to your Channel Specification by selecting Add channels » Plug-in » Min-Max. Then, select the calculation type and the channels.

FlexLogger 2024 Q2 New Features and Changes

  • Discover which FlexLogger edition is right for you.
    • Use FlexLogger Lite, the free edition of FlexLogger, for your basic data logging applications.
    • Try a free trial of FlexLogger for advanced data logging applications.
    • Buy a complete FlexLogger license for your advanced data logging applications.
  • Reduce disk space when logging by configuring your project to log at a lower rate. Use the Logging Specification to set trigger conditions and decrease the logging rate outside of events of interest.
  • Define how you want to retain the SystemLink tags you publish from FlexLogger.

FlexLogger 2023 Q4 New Features and Changes

  • Install with less effort. FlexLogger offers streamlined installation so you do not have to make decisions about which additional software to install along with FlexLogger. You can still choose what to install by enabling Customize installation in NI Package manager.
  • No hardware? No problem. Quickly add a simulated USB data acquisition device (DAQ) from FlexLogger so you can configure your project without hardware. Refer to How FlexLogger Connects to Your Hardware for more information.
  • FlexLogger loads your projects faster. Notice up to 60% faster load times for high-channel-count projects that use formulas extensively.
  • Trigger an event with the click of a button. Refer to Initiating an Action with a Button for more information.
  • Define how FlexLogger displays the date and time on axes for time-series graphs, including the number of significant figures, so you can capture the precision of your time-series data. In your Screen document, click the time axis and modify the Display format settings in the Item configuration pane.
  • FlexLogger preserves the layout of your Channel Specification so you see only the channels you want when you reopen a saved project.
  • FlexLogger loads frequently viewed Channel Specification sections faster.
  • Map multiple channels to a Frequency Spectrum graph. Refer to Visualizing Live Data with Indicators and Graphs for more information.
  • More intuitive timing when logging your data. The toolbar timer and time-based triggers start when you click RUN.
  • Add an Integral channel to your Channel Specification to calculate additional physical parameters for your system. For example, integrate your accelerometer data to get velocity and integrate velocity to get displacement over time.
  • Support for USB-6008 and USB-6009 low-cost, multifunction DAQ devices. Refer to Supported Hardware for more information.
  • Use the FlexLogger Python API to programmatically get and set trigger settings for your project.

FlexLogger 2023 Q3 New Features and Changes

  • FlexLogger now provides averaging on the undecimated data for high-speed graphs at any zoom level.
  • FlexLogger no longer supports publishing or consuming data locally using the NI Web Server Configuration. Instead, publish FlexLogger data to LabVIEW using a remote SystemLink server. You can also automate FlexLogger using the FlexLogger Python API or design custom plug-ins for FlexLogger using the FlexLogger Plug-in Development Kit.
  • Use the IEEE 1588 protocol to synchronize your time-sensitive networking (TSN)–enabled CompactDAQ chassis. In FlexLogger, navigate to File » Preferences » General, check Enable multi-chassis and network synchronization, and select 1588.
  • See a table with statistical information for all channels on a graph. On your Screen document, click a graph to open the Item configuration pane located on the right side of the window. In the Parts section, enable Statistics legend.
  • Zoom in on all graphs simultaneously to get a closer look at your data. On your Screen document, click Pause all graphs . Then, click Synchronize zoom of paused graphs and zoom in on one graph. FlexLogger zooms in on the same interval of time on all graphs.
  • Display strings published by plug-in channels you created with the FlexLogger Plug-in Development Kit and added to FlexLogger. In your FlexLogger Screen document, add a Text Box Indicator from the Text menu. Map the indicator to the plug-in string channel you want to see strings from.
  • Support for LabVIEW 2023 in the FlexLogger Plug-in Development Kit 1.7.
  • Use the FlexLogger Python API to programmatically register and handle alarms, log file events, and test session events. Log file events include creating and completing a log file and test session events include starting and stopping a test.
  • Use the FlexLogger Python API to programmatically get the name of your FlexLogger project.

FlexLogger 2023 Q2 New Features and Changes

  • Collect more accurate thermocouple measurements by using a sensor as your cold junction compensation (CJC) source instead of a constant value. In the thermocouple channel configuration dialog, set the CJC source to Sensor and map to another RTD or thermocouple channel in the same chassis to use as the CJC source.
  • Synchronize digital lines in your 62xx multifunction I/O device with analog channels configured on the same device.
  • Synchronize the onboard counters in your 62xx and 63xx multifunction I/O devices with analog channels configured on the same device.
  • Configure FlexLogger to retry publishing files to SystemLink after restoring a lost connection.
  • Send strings from third party devices to FlexLogger using the FlexLogger Plug-in Development Kit 1.6.
  • Use the FlexLogger Python API to programmatically update the log file description and add or modify several test properties at once in your Logging Specification document.
  • Halt or resume all graphs on your Screen document simultaneously by toggling Pause all graphs .
  • Avoid manual data entry when specifying multiple scaling factors for your channel. In the channel configuration, select Table as the scaling type, copy two columns of space or tab separated values, and paste the values into the table.
  • See the average value for a segment of data on a graph. In your Screen document, hover over the data to see statistical information.
  • Configure your RMS and Mean channels to average all the data you collected for the channel since starting the test or opening a project.
  • (Preview Feature) Reduce disk space when logging in FlexLogger by configuring your project to log at a low-fidelity rate. Use the Logging Specification to set trigger conditions and enable low-fidelity logging.

FlexLogger 2023 Q1 New Features and Changes

  • Support all 62xx multifunction I/O data acquisition devices: PCI, PCI Express (PCIe), PXI, PXI Express (PXIe), and USB. Refer to Supported Hardware for specific model support information.
  • Support for PCIe 63xx multifunction I/O data acquisition devices. Refer to Supported Hardware for specific model support information.
  • Use the FlexLogger Python API to programmatically configure the data acquisition rate of your channels.
  • Use the FlexLogger Python API to programmatically save your FlexLogger projects.
  • Upload data files you renamed in FlexLogger to SystemLink so you can keep track of project files across systems. Rename a data file in the FlexLogger Data tab. If you already published the file to SystemLink, FlexLogger launches the Rename dialog. Select Rename and upload file to upload the renamed file to SystemLink.
  • Support for LabVIEW 2022 in the FlexLogger Plug-in Development Kit 1.5.

FlexLogger 2022 Q4 New Features and Changes

  • Back up your FlexLogger data files to SystemLink Server or SystemLink Cloud without publishing test data as tags. Track the progress of your backup file uploads in the FlexLogger Data tab.
  • See the connection status between FlexLogger and SystemLink on the toolbar of your Channel Specification.
  • Show only configured channels so you can see your whole test system. In the Channel Specification, click Show configured channels . FlexLogger hides all unconfigured channels and highlights the button to indicate that you have enabled the filter.
  • Copy and paste formula-based calculated channels. Add and configure an arithmetic or Boolean formula channel in your Channel Specification. Right-click the channel to copy it. Paste the channel into an unconfigured or configured channel of the same type.

FlexLogger 2022 Q2 New Features and Changes

  • Test ECUs using A2L databases that rely on the CAN Calibration Protocol (CCP).
  • Set XNET output values outside of the minimum and maximum limits configured in your database so you can test the robustness of your ECUs.
  • Deactivate logging on specific channels. In the Channel Specification, hover over a channel and click Disable logging (). FlexLogger will no longer bold this channel in the display.
  • Scale the electrical values of a device to the physical units of a sensor using value-dependent scaling factors. Select Table as the scaling type and specify multiple electrical values and their corresponding physical values.