Setting Target Parameters in Target Sweeps
- 更新日2026-07-08
- 2分で読める
Setting Target Parameters in Target Sweeps
- Select the Mode dropdown on the top right of the main Target panel.
- Select Target Sweeps.
- Click Disabled/Enabled to enable targets. The software supports between one and three or four targets per instrument, depending on the selected personality.
-
Enter the target parameters for the target(s). You can configure the following
settings for each target based upon the mode of operation:
- Time-Frequency
- Start Time Offset—Amount of time that the pulse is delayed inside the system.
- Time Offset Rate of Change—Rate at which the pulse is delayed inside the system.
- Start Attenuation Offset—Change in power level (gains not supported) of the pulse inside the system.
- Attenuation Offset Rate of Change—Rate at which the power level changes inside the system.
- Start Frequency Offset—Absolute frequency shift to simulate a moving target.
- Frequency Offset Rate of Change—Rate at which the absolute frequency shifts.
- Range-Velocity
- Starting Range—The starting distance, in meters, at which the pulse is seen.
- Range Rate of Change—Rate at which the pulse distance changes over time in relation to the scenario duration.
- Start Attenuation Offset—Change in power level (gains not supported) of the pulse inside the system.
- Attenuation Offset Rate of Change—Rate at which the power level changes inside the system.
- Starting Relative Velocity—The initial velocity of a pulse relative to the radar source, represented as a vector quantity.
- Relative Velocity Rate of Change—Rate at which the relative velocity changes over time.
- Time-Frequency
- Set a Scenario Duration.
- Set a Target Configuration Update Rate.
- Click Send Target Configuration Sweep Parameters to build the list in software.