Options Tab - TestStand Sequence Analyzer Application

Options Tab

Use the Options tab to enable or disable the following options:

  • Analyze Skipped Steps —Enable this option to analyze steps for which you set the Run Mode option to Skip.
  • Analyze Subsequences —Enable this option to analyze sequence files that Sequence Call steps call from analyzed sequence files. When you use expressions in Sequence Call steps to call sequence files, you must add each file to the Sequence Files to Analyze list on the Files tab of the sequence analyzer application separately.
  • Analyze Model Sequence Files —Enable this option to analyze process model sequence files associated with analyzed sequence files.
  • Automatically Save Project File —Enable this option to automatically save the project file when you close the file in the TestStand Sequence Editor or sequence analyzer application. The default project ( MyAnalyzerProject.tsaproj ) the sequence editor creates at first launch enables this option. The sequence analyzer disables this option for all other analyzer project files you create.

See Also

Sequence Call Step