NationalInstruments.RFmx.InstrMX
- Updated2025-04-08
- 3 minute(s) read
Classes
Name | Description |
---|---|
RFmxException | Represents errors that occur during RFmx application execution. |
RFmxInstrMX | Defines a root class which is used to identify and control Instr signal configuration. |
RFmxInstrMXConstants | Specifies constants for I/O terminals. |
Interfaces
Name | Description |
---|---|
IList | Represents a list. Implement this interface to expose measurement functionality. |
ISignalConfiguration | Represents a signal configuration. Implement this interface to expose measurement functionality. |
Structures
None
Enumerations
Name | Description |
---|---|
RFmxInstrMXAdvanceTriggerType | Specifies whether the advance trigger is a digital edge or a software trigger. |
RFmxInstrMXChannelCoupling | Specifies whether the RF IN connector is AC- or DC-coupled on the downconverter. |
RFmxInstrMXCleanerSpectrum | Specifies how to obtain the lowest noise floor or faster measurement speed. |
RFmxInstrMXDigitizerDitherEnabled | Specifies whether dithering is enabled on the digitizer. |
RFmxInstrMXDownconverterPreselectorEnabled | Specifies whether the tunable preselector is enabled on the downconverter. |
RFmxInstrMXExportSignalSource | Routes signals (triggers, clocks, and events) to the specified output terminal. |
RFmxInstrMXFrequencySettlingUnits | Specifies the delay duration units and interpretation for LO settling. |
RFmxInstrMXInputIsolationEnabled | Specifies whether input isolation is enabled. |
RFmxInstrMXLO2ExportEnabled | Specifies whether to enable the LO2 OUT terminals in the installed devices. |
RFmxInstrMXLOInjectionSide | Enables in-band retuning and specifies the current frequency of the RF downconverter. This value is expressed in Hz. |
RFmxInstrMXLOLeakageAvoidanceEnabled | Specifies whether to reduce the effects of the instrument leakage by placing the LO outside the band of acquisition. |
RFmxInstrMXLOPllFractionalMode | Specifies whether to use fractional mode for the LO phase-locked loop (PLL). |
RFmxInstrMXLOSharingMode | Specifies the RFmx session with the respective LO sharing mode. |
RFmxInstrMXLinearInterpolationFormat | Specifies the format of parameters to interpolate. |
RFmxInstrMXLoadOptions | Specifies the configurations to skip while loading from a file using the LoadConfigurations(string) method |
RFmxInstrMXMechanicalAttenuationAuto | Specifies whether RFmx chooses an attenuation setting based on the hardware settings. |
RFmxInstrMXOptimizePathForSignalBandwidth | Optimizes RF path for the signal bandwidth that is centered on the IQ carrier frequency. |
RFmxInstrMXOspDelayEnabled | Specifies whether to enable the digitizer OSP block to delay Reference Triggers, along with the data samples, moving through the OSP block. |
RFmxInstrMXOverflowErrorReporting | Configures error reporting for ADC and overflows occurred during onboard signal processing. Overflows lead to clipping of the waveform. |
RFmxInstrMXPersonalities | Specifies the personality of the signal if the signal exists. |
RFmxInstrMXPreampEnabled | Specifies whether the RF preamplifier is enabled in the system. |
RFmxInstrMXPropertyId | Specifies all the attribute identifiers. |
RFmxInstrMXRFAttenuationAuto | Specifies whether RFmx computes the RF attenuation. |
RFmxInstrMXRecommendedAcquisitionType | Returns the recommended acquisition type for the last committed measurement configuration. This method is supported when |
RFmxInstrMXRecommendedSpectralFftWindow | Returns the recommended FFT window type for spectral acquisition. This method is supported when |
RFmxInstrMXSParameterOrientation | Specifies the orientation of the data in the S2P file relative to the port you specify. The default value is Port2TowardsDut. |
RFmxInstrMXSParameterType | Returns the type of S-parameter to apply to measurements on the specified port for a Calplane. You can use the selectorString input to specify the name of the Calplane and port to configure for s-parameter. |
RFmxInstrMXSelfCalibrateSteps | Specifies the self-calibration step. |
RFmxInstrMXSelfCalibrationValidityCheck | Specifies whether RFmx validates the self-calibration data. |
RFmxInstrMXStartTriggerDigitalEdge | Specifies the active edge for the start trigger. This method is used only when you set the SetStartTriggerType(string, RFmxInstrMXStartTriggerType) method to DigitalEdge. |
RFmxInstrMXStartTriggerType | Specifies whether the start trigger is a digital edge or a software trigger. |
RFmxInstrMXTuningSpeed | Makes tradeoffs between tuning speed and phase noise. |
Delegates
None