RFmxInstrMXConstants Class
- Updated2025-10-13
- 8 minute(s) read
Specifies constants for I/O terminals.
Derives from
None
Syntax
Namespace: NationalInstruments.RFmx.InstrMX
public class RFmxInstrMXConstants
Fields
| Name | Description |
|---|---|
| ClockIn | PXIe-5663/5663E: RFmx locks the PXIe-5663/5663E to an external 10 MHz signal. Connect the external signal to the PXIe-5622 CLK IN connector, and connect the PXIe-5622 CLK OUT connector to the FREQ REF IN connector on the PXIe-5652. PXIe-5665: RFmx locks the PXIe-5665 to an external 100 MHz signal. Connect the external signal to the PXIe-5622 CLK IN connector, and connect the PXIe-5622 CLK OUT connector to the REF IN connector on the PXIe-5653. Set the SetFrequencyReferenceFrequency(string, double) method to 100 MHz. |
| ClockOut | Export the Reference Clock on the CLK OUT terminal on the digitizer. This value is not valid for the PXIe-5644/5645/5646 or PXIe-5820/5830/5831/5832/5840/5841/5842/5860. |
| DioPfi0 | |
| DioPfi1 | |
| DioPfi2 | |
| DioPfi3 | |
| DioPfi4 | |
| DioPfi5 | |
| DioPfi6 | |
| DioPfi7 | |
| DoNotExportSignal | Specifies that the signal should not be exported. |
| LOSourceAutomaticSGSAShared | Specifies that RFmx automatically configures the signal analyzer to use the LO utilized by the signal generator on the same vector signal transceiver (VST) based on the configured measurements. Note When using a DPD applied signal for performing measurements like ModAcc, PvT, or TXP, you must set the LO Leakage Avoidance Enabled property to False and LO Source property to Automatic_SG_SA_Shared. |
| LOSourceLOIn | Specifies that the LO source used to downconvert the RF input signal is connected to the LO IN connector on the front panel. |
| LOSourceNone | Specifies that no LO source is required to downconvert the RF input signal. |
| LOSourceOnboard | Specifies that the onboard synthesizer is used to generate the LO signal that downconverts the RF input signal. PXIe-5831: This configuration uses the onboard LO of the PXIe-3622, using the LO2 stage. |
| LOSourceSecondary | Specifies that the LO source uses the PXIe-5830/5831/5832/5840 internal LO. This value is valid on only the PXIe-5840 with PXIe-5653, PXIe-5831 with PXIe-5653 (LO1 stage only), PXIe-5832 with PXIe-5653 (LO1 stage only). |
| LOSourceSGSAShared | Specifies that the internal LO can be shared between RFmx and RFSG sessions. RFmx selects an internal synthesizer and the synthesizer signal is switched to both the RX and TX mixers. This value is valid only on the PXIe-5830/5831/5832/5841/5842. |
| None | The Reference Clock is not exported. This value is not valid for the PXIe-5644/5645/5646. |
| OnboardClock | PXIe-5663/5663E: RFmx locks the PXIe-5663/5663E to the PXIe-5652 LO source onboard clock. Connect the REF OUT2 connector (if it exists) on the PXIe-5652 to the PXIe-5622 CLK IN terminal. On versions of the PXIe-5663/5663E that lack a REF OUT2 connector on the PXIe-5652, connect the REF IN/OUT connector on the PXIe-5652 to the PXIe-5622 CLK IN terminal. |
| Pfi0 | The signal is exported to the PFI 0. |
| Pfi1 | The signal is exported to the PXI 1. |
| PxiClock | PXIe-5668: Lock the PXIe-5653 to the PXI backplane clock. Connect the PXIe-5606 LO2 OUT to the LO2 IN connector on the PXIe-5624. |
| PxiClockMaster | PXIe-5831 with PXIe-5653: RFmx configures the PXIe-5653 to export the reference clock and configures the PXIe-5820 and PXIe-3622 to use PXI_Clock as the reference clock source. You must connect the PXIe-5653 REF OUT (10 MHz) connector to the PXI chassis REF IN connector. |
| PxieDStarBLine | The signal is exported to the PXIe DStar B trigger line. This value is valid only for PXIe-5820/5830/5831/5832/5840/5841/5842/5860. |
| PxieDStarCLine | The signal is exported to the PXIe DStar C trigger line. This value is valid only for PXIe-5820/5830/5831/5832/5840/5841/5842/5860. |
| PxiStarLine | The signal is exported to the PXI star trigger line. |
| PxiTriggerLine0 | The signal is exported to the PXI trigger line 0. |
| PxiTriggerLine1 | The signal is exported to the PXI trigger line 1. |
| PxiTriggerLine2 | The signal is exported to the PXI trigger line 2. |
| PxiTriggerLine3 | The signal is exported to the PXI trigger line 3. |
| PxiTriggerLine4 | The signal is exported to the PXI trigger line 4. |
| PxiTriggerLine5 | The signal is exported to the PXI trigger line 5. |
| PxiTriggerLine6 | The signal is exported to the PXI trigger line 6. |
| PxiTriggerLine7 | The signal is exported to the PXI trigger line 7. |
| ReferenceIn | PXIe-5663/5663E: Connect the external signal to the PXIe-5652 REF IN/OUT connector. Connect the REF OUT2 connector (if it exists) on the PXIe-5652 to the PXIe-5622 CLK IN terminal. PXIe-5665: Connect the external signal to the PXIe-5653 REF IN connector. Connect the 100 MHz REF OUT terminal on the PXIe-5653 to the PXIe-5622 CLK IN connector. If your external clock signal frequency is set to a frequency other than 10 MHz, set the SetFrequencyReferenceFrequency(string, double) method according to the frequency of your external clock signal. |
| ReferenceIn2 | PXIe-5840 with PXIe-5653: RFmx locks the reference clock to the clock sourced at the PXIe-5840 REF IN terminal that is previously configured by an NI-RFSG session. Connect the NI-5840 REF OUT connector to the PXIe-5653 REF IN connector. |
| ReferenceOut | Export the clock on the REF IN/OUT terminal on the PXIe-5652, the REF OUT terminals on the PXIe-5653, or the REF OUT terminal on the PXIe-5694, PXIe-5644/5645/5646, or PXIe-5820/5830/5831/5832/5840/5841/5842/5860. |
| ReferenceOut2 | Export the clock on the REF OUT2 terminal on the PXIe-5652. This value is valid only for the PXIe-5663E. |
| TimerEvent | The trigger is received from the timer event. This value is valid only for PXIe-5820/5840/5841/5842/5860 and for digital edge advance triggers on PXIe-5663E/5665. |