Groups

Group members

NameDescription
RFMXINSTR_ATTR_AMPLITUDE_SETTLING

Specifies the amplitude settling accuracy value. This value is expressed in decibels. RFmx waits until the RF power attains the specified accuracy level after calling the RFmx Initiate function.

RFMXINSTR_ATTR_CHANNEL_COUPLING

Specifies whether the RF IN connector is AC- or DC-coupled on the downconverter.

RFMXINSTR_ATTR_CLEANER_SPECTRUM

Specifies how to obtain the lowest noise floor or faster measurement speed.

RFMXINSTR_ATTR_COMMON_MODE_LEVEL

Specifies the common-mode level presented at each differential input terminal. The common-mode level shifts both positive and negative terminals in the same direction. This must match the common-mode level of the device under test (DUT). This value is expressed in Volts.

RFMXINSTR_ATTR_DIGITAL_GAIN

Specifies the scaling factor applied to the time-domain voltage data in the digitizer. This value is expressed in dB. RFmx does not compensate for the specified digital gain.

RFMXINSTR_ATTR_DIGITIZER_DITHER_ENABLED

Specifies whether dithering is enabled on the digitizer.

RFMXINSTR_ATTR_DOWNCONVERTER_GAIN

Returns the net signal gain for the device at the current RFmx settings and temperature. RFmx scales the acquired I/Q and spectrum data from the digitizer using the value of this attribute.

RFMXINSTR_ATTR_DOWNCONVERTER_PRESELECTOR_ENABLED

Specifies whether the tunable preselector is enabled on the downconverter.

RFMXINSTR_ATTR_FFT_WIDTH

Specifies the FFT width of the device. The FFT width is the effective bandwidth of the signal path during each signal acquisition.

RFMXINSTR_ATTR_FREQUENCY_SETTLING

Specifies the value used for LO frequency settling.

RFMXINSTR_ATTR_FREQUENCY_SETTLING_UNITS

Specifies the delay duration units and interpretation for LO settling.

RFMXINSTR_ATTR_IF_FILTER_BANDWIDTH

Specifies the IF filter path bandwidth for your device configuration.

RFMXINSTR_ATTR_IF_OUTPUT_POWER_LEVEL_OFFSET

Specifies the power offset by which to adjust the default IF output power level. This value is expressed in dB.

RFMXINSTR_ATTR_INPUT_ISOLATION_ENABLED

Specifies whether input isolation is enabled.

RFMXINSTR_ATTR_MIXER_LEVEL

Specifies the mixer level. This value is expressed in dBm.

RFMXINSTR_ATTR_MIXER_LEVEL_OFFSET

Specifies the number of dB by which to adjust the device mixer level.

RFMXINSTR_ATTR_NUMBER_OF_RAW_IQ_RECORDS

Returns the number of raw IQ records to acquire to complete measurement averaging.

RFMXINSTR_ATTR_OPTIMIZE_PATH_FOR_SIGNAL_BANDWIDTH

Optimizes RF path for the signal bandwidth that is centered on the IQ carrier frequency.

RFMXINSTR_ATTR_OSP_DELAY_ENABLED

Specifies whether to enable the digitizer OSP block to delay Reference Triggers, along with the data samples, moving through the OSP block.

RFMXINSTR_ATTR_OVERFLOW_ERROR_REPORTING

Configures error reporting for ADC and overflows occurred during onboard signal processing. Overflows lead to clipping of the waveform.

RFMXINSTR_ATTR_PHASE_OFFSET

Specifies the offset to apply to the initial I and Q phases.

RFMXINSTR_ATTR_PREAMP_ENABLED

Specifies whether the RF preamplifier is enabled in the system.

RFMXINSTR_ATTR_RF_ATTENUATION_STEP_SIZE

Specifies the step size for the RF attenuation level. This value is expressed in dB. The actual RF attenuation is coerced up to the next highest multiple of the specified step size. If the mechanical attenuators are not available to implement the coerced RF attenuation, the solid state attenuators are used.

RFMXINSTR_ATTR_RF_HIGHPASS_FILTER_FREQUENCY

Specifies the maximum corner frequency of the high pass filter in the RF signal path. The device uses the highest frequency high-pass filter option below or equal to the value you specify and returns a coerced value. Specifying a value of 0 disables high pass filtering silly.

RFMXINSTR_ATTR_SMU_CHANNEL

Specifies the output channel to be used for noise figure (NF) measurement in RFmx.

RFMXINSTR_ATTR_SMU_RESOURCE_NAME

Specifies the resource name assigned by Measurement and Automation Explorer (MAX) for NI Source Measure Units (SMU) which is used as the noise source power supply for Noise Figure (NF) measurement, for example, PXI1Slot3, where PXI1Slot3 is an instrument resource name. SMU Resource Name can also be a logical IVI name.

RFMXINSTR_ATTR_SUBSPAN_OVERLAP

Use subspan overlap process to eliminate or reduce analyzer spurs. To enable this feature, specify a non-zero percentage overlap between consecutive subspans in a spectrum acquisition.

RFMXINSTR_ATTR_TEMPERATURE_READ_INTERVAL

Specifies the minimum time difference between temperature sensor readings. This value is expressed in seconds.

RFMXINSTR_ATTR_THERMAL_CORRECTION_HEADROOM_RANGE

Specifies the expected thermal operating range of the instrument from the self-calibration temperature returned from the RFMXINSTR_ATTR_DEVICE_TEMPERATURE attribute. This value is expressed in degree Celsius.

RFMXINSTR_ATTR_THERMAL_CORRECTION_TEMPERATURE_RESOLUTION

Specifies the temperature change required before RFmx recalculates the thermal correction settings when entering the running state. This value is expressed in degree Celsius.

Attachments

None