1073356801
|
0x3FFA2001
|
NISWITCH_WARN_PATH_REMAINS |
Some connections remain after disconnecting. |
|
1073356802
|
0x3FFA2002
|
NISWITCH_WARN_IMPLICIT_CONNECTION_EXISTS |
The channels are implicitly connected. |
|
-1074130943
|
0xBFFA1001
|
NISWITCH_ERROR_TRIGGER_NOT_SOFTWARE |
The trigger source is not a software trigger. |
|
-1074126847
|
0xBFFA2001
|
NISWITCH_ERROR_INVALID_SWITCH_PATH |
Invalid path string. |
|
-1074126846
|
0xBFFA2002
|
NISWITCH_ERROR_INVALID_SCAN_LIST |
Invalid Scan List string. |
|
-1074126845
|
0xBFFA2003
|
NISWITCH_ERROR_RSRC_IN_USE |
One of the channels is a configuration channel that is in use or is a
common multiplexer channel that is in use. |
|
-1074126844
|
0xBFFA2004
|
NISWITCH_ERROR_EMPTY_SCAN_LIST |
The scan list string is empty. |
|
-1074126843
|
0xBFFA2005
|
NISWITCH_ERROR_EMPTY_SWITCH_PATH |
The path string is empty. |
|
-1074126842
|
0xBFFA2006
|
NISWITCH_ERROR_SCAN_IN_PROGRESS |
The switch module is currently in scanning mode, and the operation
cannot be performed at this time. |
|
-1074126841
|
0xBFFA2007
|
NISWITCH_ERROR_NO_SCAN_IN_PROGRESS |
The switch module is not currently in scanning mode, and the operation
cannot be performed at this time. |
|
-1074126840
|
0xBFFA2008
|
NISWITCH_ERROR_NO_SUCH_PATH |
No explicit path exists between the two channels. |
|
-1074126839
|
0xBFFA2009
|
NISWITCH_ERROR_IS_CONFIGURATION_CHANNEL |
You cannot make an explicit connection to a configuration
channel. |
|
-1074126838
|
0xBFFA200A
|
NISWITCH_ERROR_NOT_A_CONFIGURATION_CHANNEL |
One of the non-terminal channels in the path is not a configuration
channel. |
|
-1074126837
|
0xBFFA200B
|
NISWITCH_ERROR_ATTEMPT_TO_CONNECT_SOURCES |
You cannot make a connection between two different sources. |
|
-1074126836
|
0xBFFA200C
|
NISWITCH_ERROR_EXPLICIT_CONNECTION_EXISTS |
An explicit connection between the channels already exists. |
|
-1074126835
|
0xBFFA200D
|
NISWITCH_ERROR_LEG_MISSING_FIRST_CHANNEL |
A leg in the path does not begin with a channel name. |
|
-1074126834
|
0xBFFA200E
|
NISWITCH_ERROR_LEG_MISSING_SECOND_CHANNEL |
A leg in the path is missing the second channel. |
|
-1074126833
|
0xBFFA200F
|
NISWITCH_ERROR_CHANNEL_DUPLICATED_IN_LEG |
The first and second channels in the leg are the same. |
|
-1074126832
|
0xBFFA2010
|
NISWITCH_ERROR_CHANNEL_DUPLICATED_IN_PATH |
A channel name is duplicated in the path string. |
|
-1074126831
|
0xBFFA2011
|
NISWITCH_ERROR_PATH_NOT_FOUND |
No path was found between the two channels. |
|
-1074126830
|
0xBFFA2012
|
NISWITCH_ERROR_DISCONTINUOUS_PATH |
The first channel of a leg in the path is not the same as the second
channel in the previous leg. |
|
-1074126829
|
0xBFFA2013
|
NISWITCH_ERROR_CANNOT_CONNECT_DIRECTLY |
The path contains a leg with two channels that cannot be directly
connected. |
|
-1074126828
|
0xBFFA2014
|
NISWITCH_ERROR_CHANNELS_ALREADY_CONNECTED |
A leg in the path contains two channels that are already directly
connected. |
|
-1074126827
|
0xBFFA2015
|
NISWITCH_ERROR_CANNOT_CONNECT_TO_ITSELF |
A channel cannot be connected to itself. |
|
-1074126826
|
0xBFFA2016
|
NISWITCH_ERROR_MAX_TIME_EXCEEDED |
Maximum time exceeded before the operation completed. |
|
-1074118655
|
0xBFFA4001
|
NISWITCH_ERROR_SESSION_ALREADY_OPEN |
Another process has already opened a session to this switch module.
|
|
-1074118654
|
0xBFFA4002
|
NISWITCH_ERROR_INVALID_RESOURCE_DESCRIPTOR |
Invalid resource name. |
|
-1074118653
|
0xBFFA4003
|
NISWITCH_ERROR_SCANNING_NOT_SUPPORTED |
You have set an attribute or called a function that is only used for
scanning, and this switch module does not support scanning (or this module
does not support scanning in the current topology). |
|
-1074118652
|
0xBFFA4004
|
NISWITCH_ERROR_MUST_SPECIFY_MODULE |
You have indicated that a non-cabled module should get its trigger from
the rear connector, and the niSwitch software could not automatically detect
which cabled module to route the trigger from. Be more specific (ie, specify
Rear Connector of Module X). |
|
-1074118651
|
0xBFFA4005
|
NISWITCH_ERROR_MODULE_FIFO_LENGTH_EXCEEDED |
The scan list commands exceeds the size of memory on the switch
module. |
|
-1074118650
|
0xBFFA4006
|
NISWITCH_ERROR_HW_COMMUNICATE_TMO |
Error communicating with hardware. Internal timeout occurred waiting for
hardware response. |
|
-1074118649
|
0xBFFA4007
|
NISWITCH_ERROR_TTL_BUS_REQUIRED |
Expecting trigger or scan advanced bus to be one of the TTL lines (TTL
0-TTL 7). |
|
-1074118648
|
0xBFFA4008
|
NISWITCH_ERROR_MODULE_IS_BBM_ONLY |
This module requires scan mode to be Break Before Make. |
|
-1074118647
|
0xBFFA4009
|
NISWITCH_ERROR_1127_TTL1_CONFLICT |
TTL 1 conflict detected. SCXI 1127 modules constantly use the TTL 1
line. Use a different line, or power down the chassis and remove all 1127
modules from it. |
|
-1074118645
|
0xBFFA400B
|
NISWITCH_ERROR_INVALID_DRIVER_SETUP_STRING |
The driver setup string is invalid. |
|
-1074118644
|
0xBFFA400C
|
NISWITCH_ERROR_TOPOLOGY_NOT_SUPPORTED |
No legacy device supports the specified topology. Use a different
topology, or configure the device under DAQmx and use the DAQmx resource
descriptor. |
|
-1074118643
|
0xBFFA400D
|
NISWITCH_ERROR_INVALID_TOPOLOGY |
The specified topology string is invalid. |
|
-1074118642
|
0xBFFA400E
|
NISWITCH_ERROR_HARDWARE_UNEXPECTEDLY_RESET |
The device was unexpectedly power cycled. Close and re-open the
session. |
|
-1074118641
|
0xBFFA400F
|
NISWITCH_ERROR_HANDSHAKING_INITIATION_CONFLICT |
The values for Handshaking Initiation and Trigger Input are
incompatible. An Immediate Trigger Input is not compatible with Measurement
Device Initiated (or DMM Initiated) Handshaking Initiation. |
|
-1074118639
|
0xBFFA4011
|
NISWITCH_ERROR_DAQMX_DESCRIPTOR_LEGACY_RSC_TYPE |
A DAQmx resource descriptor was specified, but the driver setup string
specifies a Legacy resource type. |
|
-1074118638
|
0xBFFA4012
|
NISWITCH_ERROR_AMBIGUOUS_MODEL_CODE |
Model code specified in the driver setup string is ambiguous. Multiple
switches match the specified model code. |
|
-1074118637
|
0xBFFA4013
|
NISWITCH_ERROR_TRIGGER_INPUT_NOT_SUPPORTED |
The trigger input specified is not supported by the device. |
|
-1074118636
|
0xBFFA4014
|
NISWITCH_ERROR_INVALID_TERMINALBLOCK_FOR_TOPOLOGY |
The configured terminal block is invalid for current topology. |
|
-1074118635
|
0xBFFA4015
|
NISWITCH_ERROR_CANT_INVERT_WHEN_SOURCE_EQUALS_DEST |
Signal cannot be inverted when the signal source equals the
destination. |
|
-1074118634
|
0xBFFA4016
|
NISWITCH_ERROR_CONFLICTING_TRIGGER_ROUTE_EXISTS |
Requested trigger route cannot be made because a conflicting trigger
route already exists. |
|
-1074118633
|
0xBFFA4017
|
NISWITCH_ERROR_INVALID_VALUE_FOR_DEVICE |
This device does not support the specified value for this attribute or
operation. |
|
-1074118632
|
0xBFFA4018
|
NISWITCH_ERROR_TRIGGER_POLARITY_CONFLICT |
Trigger input polarity and scan advanced output polarity must be the
same on this particular switch device. |
|
-1074118629
|
0xBFFA401B
|
NISWITCH_ERROR_RESERVATION_ERROR |
Reservation error. |
|
-1074118628
|
0xBFFA401C
|
NISWITCH_ERROR_ANALOG_BUS_INVALID |
Analog bus invalid |
|
-1074118627
|
0xBFFA401D
|
NISWITCH_ERROR_POWER_LIMIT_EXCEEDED |
Power limit exceeded for the switch carrier. |
|
-1074118626
|
0xBFFA401E
|
NISWITCH_ERROR_DEVICE_SELF_TEST_FAILED |
Device self-test failed. |
|
-1074118625
|
0xBFFA401F
|
NISWITCH_ERROR_CARD_DETECTED_DOES_NOT_MATCH_EXPECTED_CARD |
One or more cards for your NI SwitchBlock device have been inserted and
or removed while your system was powered on. This can lead to unexpected
behavior. Restart your system. |
|
-1074118624
|
0xBFFA4020
|
NISWITCH_ERROR_ANALOG_BUS_STATE_INCONSISTENT |
An expansion bridge has been inserted or removed while your system is
powered on. This can lead to unexpected behavior. Restart your
system. |
|
-1074118623
|
0xBFFA4021
|
NISWITCH_ERROR_FIVE_VOLT_DETECT_FAILED |
The 5 V fuse on your NI SwitchBlock carrier is blown. Refer to your
documentation for help with replacing the fuse. |
|
-1074118622
|
0xBFFA4022
|
NISWITCH_ERROR_SLOT_POWER_LIMIT_EXCEEDED |
Power limit exceeded for a specific slot in the switch carrier. |
|
-1074118621
|
0xBFFA4023
|
NISWITCH_ERROR_CANNOT_EXCEED_RELAY_DRIVE_LIMIT |
The number of relays attempted to be driven on this device has exceeded
the relay drive limit for this device. |
|
-1074118620
|
0xBFFA4024
|
NISWITCH_ERROR_INVALID_CONNECTION_LIST |
Invalid NI-SWITCH connection list. |
|
-1074118619
|
0xBFFA4025
|
NISWITCH_ERROR_DISCONNECTION_PATH_NOT_SAME_AS_EXISTING_PATH |
Disconnection path is not the same as the existing path. |
|
-1074118618
|
0xBFFA4026
|
NISWITCH_ERROR_INVALID_RELAY_NAME |
Specified relay name is invalid for this device. |
|
-1074118617
|
0xBFFA4027
|
NISWITCH_ERROR_ANALOG_BUS_SHARING_DIFFERENT_WIRE_MODES |
Unable to connect channels composed of different wire modes through the
analog bus. Disconnect any devices of different wire modes from the analog
bus before routing this device through the analog bus. |