ERR LED Indicators
- Updated2025-01-22
- 1 minute(s) read
The following table lists the ERR (error) LED indicators.
| LED Color | LED Pattern | Indication |
|---|---|---|
| Red | Off | There is no error. |
| Continuously blinks | There is an invalid configuration from an unsupported module, bad device profile, object dictionary, or configuration. | |
| Blinks once and pauses | There is an unsolicited change and the NI-9145 or module is in an emergency condition. | |
| Blinks twice and pauses | There is an application watchdog timeout. The slave did not receive a scheduled EtherCAT telegram. | |
| Solid | There is a Process Data Interface (PDI) watchdog timeout. The slave failed to transfer I/O data in scheduled time. | |
| Flickering | There is a booting error from corrupt firmware or a hardware error. |