LabVIEW Simulation Interface Toolkit API Reference

SIT Run Pause Stop VI

  • Updated2023-02-21
  • 3 minute(s) read

SIT Run Pause Stop VI

Owning Palette: User Interface VIs

Requires: Simulation Interface Toolkit

Runs, pauses, or stops the simulation.

Example

SIT Reference in specifies information about the current simulation.
TCP Connection specifies the TCP reference for the current connection to the SIT Server.
Model Name specifies the name of the current model.
Server Type specifies the type of execution host on which the SIT Server is running.

0Simulation Environment (default)—Specifies that the SIT Server is running on an execution host that is running The MathWorks, Inc. MATLAB® application software.
1MATRIXx—Specifies that the SIT Server is running on an execution host that is running Xmath. The LabVIEW Simulation Interface Toolkit does not currently support this option.
2RT—Specifies that the SIT Server is running on a real-time (RT) target.
Operation specifies the action to perform on the simulation.

0Run (default)—Runs the simulation.
1Pause—Pauses the simulation.
2Stop—Stops the simulation.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
SIT Reference out returns information about the current simulation.
TCP Connection returns the TCP reference for the current connection to the SIT Server.
Model Name returns the name of the current model.
Server Type returns the type of execution host on which the SIT Server is running.

0Simulation Environment (default)—Specifies that the SIT Server is running on an execution host that is running The MathWorks, Inc. MATLAB® application software.
1MATRIXx—Specifies that the SIT Server is running on an execution host that is running Xmath. The LabVIEW Simulation Interface Toolkit does not currently support this option.
2RT—Specifies that the SIT Server is running on a real-time (RT) target.
error out contains error information. This output provides standard error out functionality.

Example

Refer to the batch simulation VI in the labview\examples\Simulation Interface\Batch Simulation directory for an example of using the SIT Run Pause Stop VI.