Use the reducing loading of data to load only specific values from a data channel into the Data Portal. A window covers the data channel in steps of a specific interval width and loads one value from each interval. To separate each channel of the Example.tdm data set into 100 intervals and to always load the first value of these intervals, complete the following steps:
- Select DIAdem NAVIGATOR.
-
Select File»Open.
-
Navigate to the Example.tdm data set in the user folder.
-
Click Data Reduction.
-
Select the Reduction method No. of intervals.
-
Enter 100 as the No. of intervals.
-
Select the Reduction mode per interval 1st value.
-
Click Load. DIAdem partitions each channel of the data set into 100 intervals and loads from these intervals the first value respectively.