Commit Log VI
Commit Log receives measurement details and attachment references that were added to the Datalogger reference previously (by the Add Measurement VI, Add Multiple Measurement VI, and the Attach VIs) and commits them to the data log.
Note The Logging Library does not support simultaneously committing more than one
measurement to the data log. Use the Commit Log VI after every
measurement VI in the test program before initiating a new measurement.

| Parameter | Required? | Data Type | Description |
|---|---|---|---|
| BDC Datalogger In | Yes | Reference | Reference to the Datalogger. |
| Error In | Yes | Cluster | Describes error conditions that occur before this node runs. This input provides standard error in functionality. |
| BDC Datalogger Out | - | Reference | Reference to the Datalogger. |
| Error Out | - | Cluster | Contains error information. This output provides standard error out functionality. |