NI-FGEN 21.3 Readme

October 2021

This file contains important information about NI-FGEN, including installation instructions, supported operating systems, new features and application software.

You can find more release information on ni.com.

  • NI-FGEN Release Notes: Known issues, bugs fixed since the last release, and other notes about this release
  • NI-FGEN Manuals: New features, behavior changes, and other documentation

If you plan to use LabVIEW NXG, refer to LabVIEW NXG Support and Considerations.


Overview

System Requirements

Supported Hardware

Supported Operating Systems

Application Software Support

Installation Instructions

Product Security and Critical Updates

IVI Compliance Package Functionality

New Features

Onboard Signal Processing

Upgrading Firmware

Behavior Changes

Accessing the Help

Finding Examples

LabVIEW NXG Support and Considerations

Automating the Installation of NI Products

Using NI Software with Microsoft Windows 10

Legal Information


Overview

NI-FGEN is an NI instrument driver that enables you to implement frequency sweeping and hopping, waveform linking and looping, and frequency shift keying (FSK) modulation for complex measurement solutions. NI-FGEN is an interchangeable virtual instrument (IVI)–compliant instrument driver, and it features a set of operations and properties that exercise the functionality of the waveform or signal generator and includes an interactive soft front panel and examples.

System Requirements

NI-FGEN 21.3 has the following requirements:

  • Processor—1 GHz or faster 64-bit (x64) processor
  • RAM—2 GB RAM (64-bit)
  • A screen resolution of 1,024 x 768
  • Windows 10 with all available critical updates and service packs

Supported Hardware

The following list details the hardware models supported in NI-FGEN 21.3:

Hardware Product Supported Under Windows 10
NI-DAQmx-Based Waveform Generators
PXI/PCI-5402
PXI-5404
PXI/PCI-5406
PXI/PCI-5412
PXI/PCI-5421
PXI-5422
PXI-5441
PXIe–5442
PXIe–5450
PXIe–5451
NI 5413, 5423, and 5433 Waveform Generators
PXIe–5413
PXIe–5423
PXIe–5433

Supported Operating Systems

NI-FGEN 21.3 supports the following operating systems:

  • Windows 10
  • Windows Server 2019
  • Windows Server 2016
  • NI Linux® Real-Time

Note    NI-FGEN no longer supports Windows Vista/XP/7/8.1, Windows Server 2003/2008/2012, or any 32-bit Windows operating system. NI-FGEN 21.3 will not install or run on an unsupported OS. You cannot deploy or distribute applications that use NI-FGEN 21.3 to an unsupported OS. Additionally, after installing NI-FGEN 21.3, you cannot use any installers built on this computer with any version of LabVIEW, LabWindows™/CVI™, NI TestStand™, or Measurement Studio on an unsupported OS.

For detailed information about NI operating system support, visit http://www.ni.com/r/win32bitsupport.

Application Software Support

NI-FGEN 21.3 supports the following application software versions, including service packs. If you are not using NI application software, refer to Microsoft Visual Studio Support.

Application SoftwareVersions Supported by NI-FGEN
LabVIEW 2018, 2019, 2020, 2021
LabVIEW Real-Time Module1 2018, 2019, 2020, 2021
LabVIEW Real-Time Module with NI Linux® Real-Time 2019, 2020, 2021
LabVIEW NXG 5.0, 5.1
LabWindows™/CVI™ 2017 and later
LabWindows™/CVI™ Real-Time Module1 2017 and later

1No support for PXIe-5413/5423/5433 waveform generators

Microsoft Visual Studio Support

If you are using the NI-FGEN .NET Class Library, the .NET Framework 4.0 (minimum) is required. The NI-FGEN .NET Class Library can be used with the Visual C# or Visual Basic .NET programming languages in any Visual Studio version that can target the .NET Framework 4.0 or the .NET Framework 4.5.

To use the .NET API, you must select the .NET Framework 4.0 Languages Support or the .NET Framework 4.5 Languages Support packages in the NI-FGEN installer to install the the .NET class libraries in addition to the NI device driver. For information about versions of the .NET Framework and the drivers each supports, as well as the download location of the installer files, refer to National Instruments .NET Driver Support.

Installation Instructions

Download the NI-FGEN installer from ni.com/downloads. NI software includes NI Package Manager to handle the installation. Refer to the NI Package Manager Manual for more information about installing, removing, and upgrading NI software using NI Package Manager.

Note

  • If Windows Update is enabled, the installation process might hang if Windows Update interferes with the installation of Microsoft Visual C++ 2015 Run-Time. Visit ni.com/r/exjq43 for more information and steps to resolve this issue.
  • If you purchased this product with an NI Software Suite or NI Product Bundle, use the installation media that shipped with your purchase to install this product.
  • NI Script Editor is no longer installed with NI-FGEN.

Product Security and Critical Updates

Visit ni.com/security to view and subscribe to receive security notifications about NI products. For information about critical updates from NI, refer to Available Critical and Security Updates for NI Software.

IVI Compliance Package Functionality

NI-FGEN no longer installs IVI Compliance Package (ICP). NI-FGEN supports IVI configuration and runtime, but no longer installs the following IVI components:

  • LabVIEW and CVI IVI class driver APIs for developing IVI interchangeable applications
  • IVI Class Simulation drivers
  • IVI-COM Adapters

To use these features, you must install ICP separately. ICP is included in the Software Platform Bundle media. A stand-alone web distribution is available from ni.com/downloads.

New Features

  • NI-FGEN 21.3 adds support for NI Linux® Real-Time
  • NI-FGEN 21.3 adds support for LabVIEW 2021
  • NI-FGEN 20.0 adds support for LabVIEW 2020 and LabVIEW NXG 5.0

Onboard Signal Processing

NI-FGEN driver when used with NI Linux® Real-Time will not support Onboard Signal Processing. This feature remains supported on Windows.

Upgrading Firmware

The PXIe-5442, PXIe-5450, and PXIe-5451 have upgradeable device firmware. It is highly encouraged and may be required that you upgrade the firmware on these devices; newer firmware contains new features and important bug fixes. To update the firmware, run the Firmware Updater application for your device (54xxFirmwareUpdater_X.Y.Z.exe, where 54xx is the name of the device and X.Y.Z is the firmware version) that is installed in the Program Files (x86)\National Instruments\NI-FGEN\ directory. This application upgrades your firmware to the latest available version that works with this driver. After the application runs, you are required to power down your computer and PXI Express chassis to complete the firmware update.

Behavior Changes

  • NI-FGEN 21.3 removes support for Manual Peer-to-Peer functionality.
  • NI-FGEN 21.3 removes support for NI-HWS.
  • The NI-FGEN Soft Front Panel has been replaced by InstrumentStudio, which is automatically installed when you install the NI-FGEN driver. You can access InstrumentStudio in one of the following ways:

    • From the Windows start menu, select National Instruments»InstrumentStudio [year]. This launches InstrumentStudio and runs a soft front panel populated with devices detected on your system.
    • From Measurement & Automation Explorer (MAX), select a device and then click Test Panels.... This launches InstrumentStudio and runs a soft front panel for the device you selected.

Note   The deprecated NI-FGEN Soft Front Panel remains available for download. Visit Legacy Soft Front Panels for NI-FGEN for more information.

Accessing the Help

Refer to the NI Signal Generators Help, accessible from Start»All Programs»National Instruments»NI-FGEN»NI-FGEN Documentation, for information about NI-FGEN.

Finding Examples

You can access all the installed NI-FGEN examples for LabVIEW, LabWindows/CVI, C, and .NET at Start»All Programs»National Instruments»NI-FGEN»NI-FGEN Examples and online at ni.com/examples. Examples also are available online that demonstrate integrating NI waveform generators with NI toolkit software including the Modulation Toolkit. Refer to ni.com/examples for these examples and for more information.

Select Help»Find Examples from LabVIEW or LabWindows/CVI to launch the NI Example Finder. LabVIEW examples for NI-FGEN are located in the LabVIEW XXXX\examples\instr\niFgen directory. You can modify an example VI to fit an application, or you can copy and paste from one or more examples into a VI that you create.

The NI Example Finder offers two ways to access all installed LabVIEW example VIs and their descriptions:

  • Click the Browse tab to locate modulation examples by task at Hardware Input and Output»Modular Instruments»NI–FGEN or by directory structure at instr»niFgen.
  • Click the Search tab to search all installed examples by keyword. For example, search for "FGEN" to locate all waveform generator examples.

LabVIEW NXG Support and Considerations

The following sections detail considerations for using LabVIEW NXG with NI-FGEN.

LabVIEW NXG Hardware Support

Hardware Product Supported Under Windows 10
NI-DAQmx-Based Waveform Generators
PXI/PCI-5402
PXI-5404
2
PXI/PCI-5406
PXI/PCI-5412
PXI/PCI-5421
PXI-5422
PXI-5441
PXIe–5442
PXIe–5450
PXIe–5451
NI 5413, 5423, and 5433 Waveform Generators
PXIe–5413
PXIe–5423
PXIe–5433
2 External calibration of this module is not supported in LabVIEW NXG.

LabVIEW NXG Help

View context help in LabVIEW by pressing <Ctrl-H> and hovering over an object.

Search for items using the search bar in the upper right corner of the LabVIEW window. You can also view context help for the search results.

Additional documentation is available online at ni.com/manuals.

LabVIEW NXG Examples

Launch LabVIEW and click the Learning tab.

LabVIEW lessons are located in the Lessons tab, and LabVIEW Examples are located in the Examples tab. Follow the instructions in the lessons and examples.

Automating the Installation of NI Products

You can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes.

If the NI product you are installing uses Microsoft .NET 4.0, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.0 separately before you install NI software.

For more information about automating the installation of NI products, refer to the following KnowledgeBase articles:

Using NI Software with Microsoft Windows 10

Microsoft Windows 10 is the latest version of the Windows operating system and features significant changes compared to previous versions. Windows 10 introduces several new capabilities and also combines features from both Windows 7 and Windows 8. For more information about NI support for Windows 10, visit ni.com/windows10.


Legal Information

Copyright

© 2007–2021 National Instruments Corporation. All rights reserved.

Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.

NI respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.

End-User License Agreements and Third-Party Legal Notices

You can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:

  • Notices are located in the <National Instruments>\_Legal Information and <National Instruments> directories.
  • EULAs are located in the <National Instruments>\Shared\MDF\Legal\license directory.
  • Review <National Instruments>\_Legal Information.txt for information on including legal information in installers built with NI products.

U.S. Government Restricted Rights

If you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.

IVI Foundation Copyright Notice

Content from the IVI specifications reproduced with permission from the IVI Foundation.

The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.