This document contains the NI-EtherCat known issues that were discovered before and since the release of NI-EtherCat 2023 Q3. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
2455995 |
Unable to Import a Third-Party EtherCAT Module on 64-bit LabVIEWThird-party EtherCAT module imports fail on 64-bit LabVIEW with a memory exception when the device profile is imported. Device profiles import as expected on 32-bit LabVIEW. Workaround: 1. Manually copy the third-party ECAT slave device profile XML file to the host computer and to the the real-time target. 2. Right-click the master item in the LabVIEW Project Explorer and select New»Targets and Devices. Once the device profile XML file is copied, the third-party module appears as an available slave device and is usable on 64-bit LabVIEW. 3. Select the device, and click OK. |
Reported Version: NI-Industrial Communications for EtherCAT 2023 Q3 Resolved Version: N/A Added: N/A |
|
2648377 | 2597077 |
Cannot add offline EtherCAT master into LabVIEW project using 64-bit software versionswhen attempting to create a LabVIEW project with EtherCAT 2023 Q3 using LabView (64-bit), adding an offline EtherCAT master to the project is not supported Workaround: Workaround for the above issue could be using an online adapter (it might limit offline coding) but EtherCAT master can be used in LabVIEW 64 bit application itself. |
Reported Version: NI-Industrial Communications for EtherCAT: 2023 Q3 Resolved Version: N/A Added: N/A |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.