This document contains the ECU Measurement and Calibration Toolkit known issues that were discovered before and since the release of ECU Measurement and Calibration Toolkit 2022 Q4. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1894340 |
Error Occurs When ECUMC Requests Access to Multiple ResourcesIf
a resource is protected according to the GET STATUS command, then ECUMC
sends an UNLOCK command after each GET SEED command, independent of the seed length. This
can prompt an "ERROR_ACCESS_LOCKED" message if the resource is not protected (seed length of 0). Workaround: There is currently no known workaround for this issue. |
Reported Version: ECU Measurement and Calibration Toolkit: 21.8 Resolved Version: N/A Added: Apr 6, 2022 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.